E-4, Akshay Height II, Sai Nagar. Omkar Nagar Square, M. R. SHELOTE Manewada Ring Road, Nagpur - 27 E-mail: mrsassociat@yahoo com ASSOCIATES Cell 9422107417, 9850343776 Fax 0712-2705970 ARCHITECTURAL CONSULTANT & STRUCTURAL DESIGNERS Annexure A FORM 1 |see Regulation 3| ARCHITECT'S CERTIFICATE (To be submitted at the time of Registration of Ongoing Project and tier withdrawal of Money from Designated Account) Date o/ot| 2025 To. MODERN ARCH DEVELOPERS NAGPUR, MAHARASHTRA, 440032 Subject: Certificate of Percentage of Completion of Construction Work of MODERN HEIGHT having MahaRERA Registration Number P50500078367 being developed by MODERN ARCH DEVELOPERS Sir. VWe MRSHELOTE &ASSOCIATES have undertaken assignment as Architect /Licensed Surveyor of certifying Percentage of Completion of Construction Work of MODERN HEIGHT having MahaRERA Registration Number P50500078367 being developed by MODERN ARCH DEVELOPERS Based on Site Inspection,with respect to Layout/ each of the Building/Wing of the aforesaid Real Estate Project Icertify that as on the date of this certificate, the Percentage of Work done for each of the building/Wing of the Real Estate Project under MahaRERA is as per Table A herein below. The percentage of the work executed with respect to each of the activity of the entire phase is detailed in Table B. TABLE-A Layout /Building /Wing Number MODERN HEIGHT Sr Tasks /Activity No. Percentage of Actual Work Done (2) (As on date of the Certificate) () (3) Excavation 100.00 Basements (if any) 3 Podiums (if any) 4 Plinth 100.00 Stilt Floor 6 Slabs of Super Structure- 2 Nos of slab 24.00 7 Internal walls, Internal Plaster, Floorings, Doors and windows 0.00 within Flats/Premises 8 Sanitary Fittings within the Flat/Premises 0.00 Staircases, Lifts Wells and Lobbies at cach Floor level Overhead 0.00 and Underground Water Tanks 10 External plumbing and external plaster, elevation, completion of 0.00 terraces with waterproofing of the Buildingi Wing. Installation of Lift, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical cquipment, compliance to 11 conditions of environment/CRZ NOC, Finishing to entrance lobby/s, 0.00 plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale. Any other activities. TABLE-B Common Areas (Internal and External Develonment Works) in respect of the Registered Phase / Project Number Sr. No. Common areas and Facilities Proposed Percentage of Actual Work Done Details (Yes No) () (2) (As ondate of the Certificate) (5) (4) Internal Roads & Footpaths 222222 2222 No O.00 Proposed Water Supply Yes 3 Sewerage (Chamber, lines,Septic Tank. Yes o.00 Proposed STP) Storm Water Drains No Landscaping & Tree Planting Street Lighting 7 Community Buildings No Treatment and disposal of sewage and No sullage water. Solid Waste management & Disposal No 10 Water conservation /Rain water harvesting No 11 Energy management No 12. Fire protection and lire safety requirements Yes 0.00 Proposed 13. Electrical meter room, sub-station, Yes 0.00 Proposed receiving station 14. Others (Option to Add more). |15. Open Parking Yes 0.00 Proposed Yours Faithfully, M. R.SHELOTE ARCHITECTURAL CONSULTANT &7RUCTURAL. DECIGNER LS No. NIT-48S. NAMKC389 NM3-NMO/R/2021/APL 49 MR SHELOTE & ASSOCIATES. EATE/R/2022/APL 12 BLOCKI SIgnature & Name (IN (License no. STATE/R/2022/APL/04132 ) MODERN ARCH DEVELOPERS Agreed and Accepted by: PARTER Signature of Promoter Name: MODERN ARCH DEVELOPERS Date: