FORM.2A ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE Date: 14-07-2021 To, The Matoshree Prabha Builders & Developers, Proprietor: Rupali Gharde, House No.-19113, Prabha City, Pawangaon, Nagpur-440034 (MH) Qualitv Assurance Certificqte (certificate no. Ps0s00021sg2 for the quarter ending 30th June 20211 Subject : Certificate for quality of materials used and quality of Construction and workmanshipfor the Work of Prabha City Lotus 2,1 No of Building situated on the PLOT NO.10 CTS No.53 KH 36/1 NO demarcated by its boundaries Other Layout to the North, Road to the South, Plot No.1'l to the East ,plot No.g to the West of Division Nagpur, village Nagpur ,taluka Nagpur District plN-440030 admeasuring 1135.64 Sq'Mtrs. area being developed by Matoshree Prabha Builders & Developers Proprietorship firm of Rupali Gharde. Reference: MahaRERA Registratlon Number- p50500021 5g2 Sir, I Dhamandip Dhongale have undertaken an assignment of supervision of this real estate project. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testinq:- I have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant IS/8S/NBC code, oras per industry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have lleen tested for water absorption, crushing strength etc. as per lS 5454'.1978 or as per other relevant |S/8S/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/l{eady-m ix Concrete- It has been tcsted for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:2011 or as per other relevant lS/BSiNBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and {ittings, pipes and sanitary fittings etc (List out all items) used in this project conform to relevant IS/BS/NBC codr.. or as per standards laid down by the lndustry for a particular material. 2. Wdrkmanstip-: I hereby certifyr that work has been carried out under our supervision. We further certify that workrnanship and quality is satisfactory and up to the mark and the work has been accr:1.rtable within the permissible limits of deviations as per relevant code of practice. 3. Electrical fu'liiterials and workmanship: - Works of oi the electrical wiring/connections/lift installation/other electrical installations hlii.',,1 been carried out underauthorized/registered electrical engineer and its records lras been maintarned. The materials used conform tothe relevant l.S/ B.S/ National lt"irlCing codes or as per industry standards. 4. Structural r ,gineer: - Promote, ; )a,il ehgsged slructural engineer Mr.P.S Patankar having Licenses no. F- 121963C avir,g office Universal Annex Flat No.302 Plot No.79, Shivaji Nagar Nagpur t-r Nc 9822224906. The str,. rl i:i design of buildings in this project has been done under his supei icr, He has checked the soil report before laying PCC for foundation in consult roir with soil consultant. The formwork and concrete mix design has been don as per ls 10262'.2009 or as per other relevant codes as applicable. His perioc . ci:ecks and certificates for STABILITY and SAFETY have been kept on record. 5. Preser , rtii:n of records: - Record : rll iest results of this project have been properly kept in the prescribed formats ir r,.,r I be preserved at least up to the defect liability period or for the period as requir< b5, any other provision of law. Yours Fa ,rfuily, *t"t Dhaman :p Dhongale Site Engi :er Mob Nc'. 67"i511189 Place: FJ; prii