FORM-2A ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE Date: 17-04-2021 To, The Jarry Profit, 48, Anupama Building, Sangita Building Road, Adwani Chowk, Jaripatka Nagpur-4400'1 4 (MH) Qualitv Assurance Certificate (Gertificate no. P505OOOO 4239 for the quarter ending 31th March 20211 Subject : Certificate for quality of materials used and quality of Construction and workmanship for the Work of Anupama Pearl Regency,of 1 No. of Building situated on the Plot No1 17,118 demarcated by its boundaries, 30 Mtr Wide Road to the North, Other Layout to the South, Plot No.116 to the East, Plot No.119 to the West of Division Nagpur ,village Nagpur ,taluka Nagpur, DistrictPlN-4400'13 admeasuring 463.21Sq.Mtrs. area being developed by Jarry Profit. Reference: MahaRERA Registration Number- P50500004233 Sir, I Rajesh Batwani have undertaken an assignment of supervision of this real estate project. Our ResponsibilitY: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testing:- I have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lS/85/NBC code, oras per industry standards and its results are within the permissible limits. ii. Goarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant IS/BS/NBC code or asper industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for ,water absorption, crushing strength etc. as per lS 5454.1g78 or as per other relevant |S/8S/NBC code or as per industry standards and its results are within permissible limits. iv. Goncrete/Ready-m ix Concrete- It has been tested for compressive strength for various periods as per 15456:2000 and lS 119g or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per lS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Othei materials like sand, crushed sand, floor tiles, fixtures and {ittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the lndustry for a particular material. 2. Workmanship:- I hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - Works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer Mr.P.S Patankar having Licenses no. F- 1219630 having office Universal Annex Flat No.302 Plot No.79, Shivaji Nagar Nagpur Cell No. 9822224906. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. Engineer/ Partner Mob No.9370973088 Place: Nagpur