ffiry HIMMAT A. AKHARE OFFICE:- SHOPNO.-5, Cl BLOCK PLANNING, DESIGNING, CONSTRUCTION AND TECHNICAL CONSULTAIIT Anncxurc A RAM LA)O\,IAN SANKUL MARKET RAMPUR CAMP ROAD, AMRAVATI Reg. o. AMC M&L 05175 FORM 2A (see Regulation 3A) ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (To be submitted at end of the Financial Year) Date:- 3110312023 To, The Shri Aditya Engineers & developers Parlner's Gopal Bondraji Ingle, & Akshay Babarao Ingle Subject: Certificate for quality of materials used and quality of constructiou and workmanship for the work of SMAHI HEIGHTS having MahaRERA Registration Number C.N. No./CTS No./ Survey No" 16/4, final plot no: 5 demarcated by its boundaries service line to the North, 30 m wide road to South, adjacent layout Piot no' 4 to west side, Division Mhasala, Taluka Amravati, Dist Amravati Pin no. 444605 admeasring 552"56 sq'mts area being developed by Shri Aditya Engineers & Developers. Sir, V we Himmat Anna Akhare have undertaken assignment as Supervision of this real estate project. 1. OurresponsibilitY:- To carry out the work in accordance with the development permission and as per the approved plan, to submit certificate of supervision of work to carry out material testing in-situ or in an authorized laboratory as per prevailing and appiicable standards, to ensure quality of work and workmanship as per prescribed specifications, and as per NBC and I or other relevant code ofpractice. 1. Material Testins :' ii we have applied following mandatory checks on the basic materials used in the construction' Cement - it has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant IS/85/NBC code. or as per industry standards and its results are within the permissible limits. ll. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing vaiue, impact value as per IS 243011986 or as per other relevant IS,tsSNBC code or as per industry standards and its results are within the permissible limits. lll. Bricks/ blocks - They have been rested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/85NBC code or as per industry standards and its results are within permissible limits. rY. Concretel Ready Mix Concrete - It has been tested for compressive strength for various periods as per i5 456:20A0 and IS 1199 or as per other relevant IS/BSAIBC codes, as per industry standards and its results are within permissible limits. Steel for concrete- It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible !imits. Yr. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BSNBC code or as per standards laid down by the Industry for a particular material. 2. WorkmanshiP:- V we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - works of all the electricai wiringiconnectionsilift installatiQn/other electrical installations have been carried out under authorized./registered eleckical engineer and its records has been maintained. The materials used conform to the relevant I.S/ B.S/ National Ruilding codes or as per industry standards. 4. Structural engineer: - promoters has engaged structural. engineer Mr.Himmat A. Akhare having Licenses no. AMC M&L - 05175 .The structural design of buildings in this project has been done under his superuision. He has checked the soil reporl before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per Is 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kePt on record. 5. Preservation of records: - Record of all test results ofthis project have been properly kept in the prescribed formats and will be preserued at least up to the defect iiability period or for the period as required by any other provision oflaw 6. please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejected. Yours Faithfu11y, Architect W* Anniruddha Associcte.r Himmat A Akhare (License No, .-----------) [eg.I{o.DDMCA/nP0l UAPL,008E4 Agreed and Accepted by: Signature of Promoter Name: Adltla Engrneers & Deve.toperr Date: .fu- paftner