ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) To, The MANISHA BUILDERS AND DEVELOPERSs Quality Assurance Certificate (Certificate no AHB/09/2022 for the Year FY 2021-2022 Subject Certificate for quality of materials used and quality of Construction and Workmanship forthe Work of JAEE RESDENCY-2 No. of Building (s)/ 1 Wings (s) of the -phase of the project situated on the plot bearing C.S. No. /C.T.S. No./ Survey No./161/2 Final plot no.12,13 demarcated by its boundaries (latitude and longitude of the end points)others house to the North Road in Layout_to the South 12 M WIDE ROAD to the East Plot no.1 1B to the West of Division Amravati, Village - Amravati, Taluka -Amravati, District - Amravati, PIN - 444 603 admeasuring 522.87 sq.mts. area being developed by [promoter's Name MANISHA BUILDERS AND DEVELOPERS Reference: MahaRERA Registration Number- P50300034234 Sir, IANKITA HARIDASJI BHOMBE have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility:- and as per the accordance with the development permission TO carry out the work in of work and to carry out material testing certificate of supervision approved plan and submit workmanship as per and to ensure quality of work and in-site or in the authorized laboratory NBC and or other relevant code practice. prescribed specification, and as per 1 1. Material Testing /We, have applied following mandatory checks on the basic materials, used in the construction. i. Cement It has been tested for its fineness, soundness, setting time, compressive Strength etc. as per IS code 3535: 1986 or as per other relevant IS/BS/NBC code, or As per industry standards and its results are within the permissible limits. ii. Coarse aggregate It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/NBC code or as perindustry standards and its results are within the permissible limits. ii. Bricks/blocks They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within permissible limits. Iv. Concrete / Ready-mix Concrete- It has been tested for compressive strength for various periods as per IS 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. V. Steel for concrete It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC Code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits vi. Testing of Other materials Other materials like sand , crushed sand, floor tiles, fixtures and fittings, Pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant 1S/BS/NBC Ccode or as per standards laid down by the Industry for a particular material. 2. Workmanship: /We hereby certify that work has been carried out under our supervision . WVe further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship Works of all the electricals wiring/ connections/ lift installation / other electricalinstallations have been carried out under authorized / registered materials used engineer and its records has been maintained.The electrical or as per industry Contorm to the relevant I.S/ B.S/ National Building codes standards. 4. Structural engineer NALAMWAR Promoters has engaged structural engineer Mr._MAHESH under his The structural design of buildings in this project has been done foundation in before laying PCC for supervision. He has checked the soil report has formwork and concrete mix design consultation with soil consultant .The His other relevant codes as applicable. been done as per IS 10262:2009 or as per and SAFETY have been kept on checks and certificates for STABILITY periodic record. 5. Preservation of records: the have been properly kept in Record of all test results of this project defect liability period or be preserved at least up to the prescribed formats and will as required by any other provision of law. for the period not conforming to other item of work which were 6. Please specify materials or any and which were not rejected the standard specifications Yours Faithfully , Signature of Engineer ( Site Supervision) Name:_ANKITA HARIBASJI BHOMBE B.E.(Civil) Phone no._7218472542 Place:AMRAVATI