ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) To, The P.S. ASsoCIATES, AMRAVATI 444602), Quality Assurance Certificate (Certificate no AHB/15/2022 for the year FY 2021-2022_) Subject Certificate for quality of materials used and quality of Construction and Workmanship for the Work of MAHALAXMI PLAZA No. of Building (s/ 1 Wings (s) ofthe_-phase of the project situated on the plot bearing C.S. No./C.T.S. No./ Survey No. / Final plot no.27 S No.34/2 demarcated by its boundaries (latitude and longitude of the end North Plot No.26 Part points) ROAD to the to the South_Polt No.28 to the East, SERVICE lane TO THE WEST of Division Amravati . village AMRAVATI (M. cORP) taluka AMRAVATIL_District_AMRAVATI_PIN_444604 admeasuring 411.70 sq.mtrs. area being developed by Promoter's Name P. S. ASSOCIATES Reference: MahaRERA Registration Number- P 50300023560 Sir, IANKITA HARIDASII BHOMBE have undertaken an assignment ofsupervision of this real estate project. 1. Our Responsibility: TO carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-site or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specification, and as per NBC and or other relevant code practice. 1. Material Testing /We, have applied following mandatory checks on the basic materials, used in the construction. . Cement It has been tested for its fineness, soundness, setting time, compressive Strength etc. as per lIS code 3535: 1986 or as per other relevant IS/BS/NBC code, or As per industry standards and its results are within the permissible limits. ii. Coarse aggregate- It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant 5/85/NBC code or as per industry standards and its results are within the permissible lirnits Bricks/ blocks - ii. They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within permissible limits. Iv. Concrete / Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per limits. industry standards and its results are within permissible Steel for concrete- V. relevant IS/BS/NBC Code It has been tested per IS 2062:2011 or as per other as industry standards for tensile strength, elongation and gauge length or as per limits. etc. and its results are within permissible vi. Testing of Other materials fixtures and fittings, Pipes Other materials like sand,crushed sand, floor tiles, conform to out all items) used in this project and sanitary fittings etc. ( List as per standards laid down by the Industry for a relevant IS/BS/NBC code or particular material. 2. Workmanship: under our supervision We . that work has been carried out /We hereby certify and up to the mark and that workmanship and quality is satisfactory further certify limits of deviations as per acceptable within the permissible the work has been relevant code of practice. and workmanship: 3. Electrical Materials lift installation / other all the electrical s wiring/ connections / Works of authorized / registered out under have been carried electrical installations materials used its records has been maintained. The electrical engineer and industry National Building codes or as per conform to the relevant 1.S/ B.S/ standards. 4. Structural engineer NALANMWAR structural engineer Mr._MAHE SH Promoters has engaged under his been done this project has design of buildings in foundation in The structural betore laying PCC for checked the soil report Supervision. He has consultation with soil consultant .The formwork and concrete mix design has His other relevant codes as applicable. been done as per IS 10262:2009 or as per STABILITY and SAFETY have been kept on periodic checks and certificates for record. 5. Preservation of records: in the have been properly kept Record of all test results of this project to the defect liability period or formats and will be preserved at least up prescribed other provision of law. for the period as required by any not conforming to other item of work which were 6. Please specify materials or any and which were not rejected the standard specifications Yours Faithfully Supervision ) Signature of Engineer (Site Name:_ANKITA HARIDASJI BHOMBE_ Phone no. 7218472542 Place:AMRAVATI ANKITA BHOMBE BE.(Cvil) Consuhing Cil Engineer