'DESIGN PLI.IS* a - grouP AN ARCHITECTURAL CONSULTENCY SERVIGES 02,Ritesh plaza Swastika Nagar Nawate Square , Badnera Road, Amravati - 4{4605 Date:0710712023 To. AIT{BER BUILDERS & DEVELOPERS, THROUGH PARTNERS SMT. SEEMA SANJAY RATHI & SHRI. PRAKASH S. KELA, AMRAVATI. Subject: Certificate of Percentage of Completion of Construction Work of AnnsnR PARK having Maha RERA Registration Number P50300024763 being developed by AMBER BUILDERS & DEVELOPERS, THROUGH PARTNERS SMT. SEEMA SANJAY RATHI & SHRI. PRAKASH S. KELA, AMRAYATI. Sir. I Ar. RAHUL FARI(ADE have undertaken assignment as Architect / Licensed Surveyor of certifying Percentage of Completion of Construction Work of anntrsn PARK Having Maha RERA Registration Number P50300024763 being developed by AMBER BUILDERS & DEVELOPERS, TIIROUGII PARTNERS SMT. SEEMA SANJAY RATIII & SIIRI. PRAKASII S. KELA, AMRAVATI. Based on Site inspection, with respect to Layout I each of the Building /Wing of the aforesaid Real Estate Project, I certify that as on the date 30.06.2023 of this certificate, the Percentage of Work done for each of the building /wing of the Real Estate Project under Maha RERA is as per Table A here in below. The percentage of the rvork executed with respect to each of the activity ofthe entire phase is detailed in Table B. RAHUL FA D B"Arch. cA / 200 0264 TABLE _ A Layout/Building/wing Number "AMBER PARK" BUTLDTNG-2 WING c & D (to be prepared separately for each Layout/BuildinglWing of the pro.iect) Sr. No. Task / Activity Percentage of actual *'ork done (1) Q) (3) I Excavation 80% 2. Basements (if any) N.A. 3. Podiums (if any) N.A" 4 Plinth 80% 5 Stilt floor 95% 6. Slabs of Super Structure. 60% 7 Intemal Walls. [nternal Plaster, Flooring, Doors and t5% Windows w'ithin Flats/ Premises I Sanitary F rvithin the Flats/Premises. 00% 9 Staircases, Lifts wells and Lobbies at each Flocr level- 0a% Overhead and Underground Water Tanks. 10 The external plumbing and extemal plaster, elevation, 0a% completion of terraces *'ith Waterproofing of the BuildingiWing. li Installation of lilts. water pumps. Fire Fighting Fittings and a0% equipment as per CFO NOC- Electrical fittings. mechanical equipment. Compliance to conditions of environmentlCRZ NOC, Finishing to entrance lobbyls. plinth protection, paving of areas appurtenant to BuildingAMing. compcund rvall and all other requirements as may be required to complete the project as per specifications in agreement of Sale. Any other activities. TABLE -B Common Areas (Internal and External Development Works) in respect of the Registered Phase/Project Number Sr. Common Areas and Facilities, Proposed Percentage Details No. (Yes/No) of actual work done (1) (2) (3) (4) (s) I lnternal Roads & Footpaths YES 00% 2 Water Supply YES 009/o Sewerage ( chamber, lines . a YES B0% septic Tank. STP) 4 Strom Water Drains YES aa% 5 Landscaping & Tree Planting YES a0v, RAHUL B"Arch. f] ,: cA / 20CI 6. Street Lighting YES 00Yo 7 Community Buildings YES s0% 8 Treatment and disposal of YES A0Yo sewage and sullage watet. 9 Solid Waste management & YES a0% Disposal r0. Water conservation / YES $$Yo Rain water harvesting. I l. Energy management YES $AYo 12. Ijire protection and fire safety YES 00o/o requirements. l3 Electrical meter room. sub- YES AA/o station. receiving station. 14. Others (option to Add more). N.A. N.A. Yours Faithfully, RAHUL FA DE B.Arch. cA / 2AAV AT. RAHUL FARKADE (License No. CAl2007 I 40264) Architect's Signature & Name Agreed and Accepted by, AMBER BUILDERS & DEVELOPERS Promoter's Signature " H#i*rarBuilders & severopers 1) SMT. SEEMA SANJAY RATIII