Pratiksha A. Gurjar B. E. Civil Shop No. 27, Venus Plaza, Shegaon Naka Square, Amravati Date:09/08/2021 FORM-2A [ See MahaRERA order no. of 2018] ENGINEER's CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, TheMANISHA ANANTKUMAR LINGOT( Name &address of Promoter ), Quality Assurance Certificate (Certificate no PG/2021/31_ for the quarter ending JUN 2021 Subject: Certificate for quality of materials used and quality of Construction and Workmanship for the Work ofJAEE RESIDENCY No. of Building (s)/ 1 Wings (s) of Final the Phase of the project situated on the plot bearing C.S. No. /C.T.S. No./ Survey No./ demarcated by its boundaries (latitude and longitude of the end plot no._45/5/B/2/3_ points) PLOT NO. 1 to the North PART OF PLOT NO 3 to the South_ROAD IN LAYOUT to the East_SERVICE LANEto the West of Division_AMRAVATI_ village- AMRAVAT taluka AMRAVATI District_AMRAVATI PIN 444604 admeasuring_558.73 sq.mtrs. area being developed by [Promoter's Name MANISHA ANANTKUMAR LINGOT Reference: MahaRERA Registration Number- P50300028493 Sir, have undertaken an assignment of supervision /We_PRATIKSHA ANILRAO GURJAR of this real estate project. 1. Our Responsibility TO carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-site or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specification, and as per NBC and or other relevant code practice. 1. Material Testing /We, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive Strength etc. as per IS code 3535: 1986 or as per other relevant IS/BS/NBC code, or As per industry standards and its results are within the permissible limits. ii. Coarse aggregate- It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. ii. Bricks/ blocks They have been tested for water absorption, crushing strength etc. as per Is 5454:1978 or as per other relevant IS/85/NBC code or as per industry standards and its results are within permissible limits. v. Concrete/ Ready-mix Concrete- It has been tested for compressive strength for various periods as per 1S 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. V. Steel for concrete- It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC Code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials- Other materials like sand ,crushed sand, floor tiles, fixtures and fittings, Pipes and sanitary fittings etc. ( List out all tems) used in this project conform to relevant 1S/BS/NBC code or as per standards laid down by the Industry for a particular material. 2. Workmanship: /We hereby certify that work has been carried out under our supervision . We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship Works of all the electrical s wiring/ connections / lift installation/ other electrical installations have been carried out under authorized / electrical engineer and its records has been registered conform to the relevant 1.S/ B.S/ National maintained. The materials used Building codes or as per industry standards. 4. Structural engineer Promoters has engaged structural engineer Mr.PANKAJ DESHMUKH having Licenses no. -having oftice --cell no. The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant . The formwork and concrete mix been done as per S 10262:2009 or as design has per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records:- Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other item of work which were not the standard conforming to specifications and which were not rejected. Yours Faithfully, Signature of Engineer (Site Supervision Name:_PRATIKSHA ANILRAO GURJAR Phone no. 9158472082 Place: AMRAVATI Pratikslha Gurjar B.E.(Civil) Consulting Civil Engineer