.I . fr. Ahash Gaikwl)ad BE (Clvl), ME (Slndnl .I . +91 9420940050 I © +91 9404693082 , I home poil~. ccrn .. ~: Jain Plaza, Shop No 3, Home Point - P~,r, ,•-1,; D, ,,qninq S1•11, r,,, ,,· :,;"I'' :-·i'""' - I ? Near Amblca Urban Bank, Main Road, Chlhl, Dist. Buldarll, MS India, 443201 Reg No. CCCEA/R/2021/APL/00094 FORM-2A Date :31/ o3/ 20 ,U- [See Regulation 3A.] ENGINEERS'S CERTIFICATE FOR QUALITY ASSURA NCE (Site Supervisor's Certificate) (To be submitted at the end of Financial Year) Date: To, The Renucorp Private Limited Akola (M Corp.), Akola, Akola, 444004 Quality Assurance Certificate f ,~ (Certificate No. ~.?!J~/..f.?:-:-.tor the Year Ending .~L~J..........) Subject : Certificate for quality of materials used and quality of Constructi on and workmanship of the work of 8469 being developed by Renucorp Private Krushna Skyllne having MahaRERA Registration Number P5000007 Limited Sir, _-~J real estate project 1/WeA:~.e.: ..~t~v e undertaken an assignment of supervision of this Our Responsibility as per the approved plan, to submit To carry out the work in accordance with the development permission and or in an authorized laboratory as per prevailing certificate of supervision of work, to carry out material testing in-situ hip as per prescribed specifications, and as per and applicable standards, to ensure quality of work and workmans NBC and / or other relevant code of practice. The details of the quality are as follows : 1. Structural Design, Stability and Testing Sr. No~, Parameters Yes/No Remarks :I 1 Whether soil investigations of the site has been Yes conducted before. the structural design and soil parameters have been accounted for in the structural desi n/drawin s? 2 Whether Structural Engineer has been appointed for Yes Name: Akash Pundlik Gaikwad the project? license No: STATE/R/2025/APU17891 Mobile: 9420940050 E-mail: home intofflce mail.com 3 Whether the inspection registers, site order book Yes and quality control test registers are maintained at the site property and endorsed by the Engineer-in- Char ? • 4 Whether testing facilities to check quality of material No is available at site? Page 1 of3 ' Parameters Yes/No ••ffemarkfl ' I l '\ 5 Whether the statuary provisions for disaster Yes resistance/earthquake resistant design have been incorporated, specially in case of multi-storeyed construction? 6 Has suitable cognizance been taken on demarcated Yes Not Applicable flood lines and appropriate precautions taken for protecting the site from flooding considering local ftoodin issues? 2. Input Materials ,,, .. \ Sr. No. Yes/No \· Remarks ' 1 Whether the following building materials confirm to Yes relevant IS/BS/NBC Code, or as per Industry Standards? If es rovide details: a Cement concrete and coarse a r ate Yes IS269 15456 IS383 b Steel and its allo s Yes IS1786 c Electrical wire fittin ssories Yes As erlBC d Plumbin and san· s Yes As er IBC 2 Whether regular tests of materials and construction Yes Pankaj Laddhad Institute of Technology products are being done from accredited' labs also? &Management Studies, Chikhli Road, If es details of such labs ' ' Yel aon Buldhana 3 Whether manufacturer test certificate for cement, Yes steel, pipes etc. have been obtained and whether su I records are bein maintained? 4 Whether suitable water is being used for Yes construction? i What is the source of water? Yes • Tanker Water (ii) Has water been tested and approved by • Yes ' En ineer-jn-Char e before construction? (iii) Has water been tested subsequently as per Yes re uirement? •I 3. Quality of Workmanship Sr_ No. Parameter'$ ' ••1 J '11, I\, ! &. Remarks·· I I ' \!1 I \I I ' 1 Whether works of all the electrical Yes wiring/connections/lift installation/other electrical instaflations have been carried out under authorized/registered electrical engineer and whether records of the same has been maintained? 2 Whether all related works of plumbing & sanitary Yes including installation of water supply systems, drainage systems, sewage systems, sinks, toilets etc. have been carried out under authorized/registered plumbers/sanitary contractors and whether records of the same has been maintained? 3 Whether all the work is being carried out under Yes supervision of experienced and skilled professional? Fur:ther, whether the workmanship and quality is satisfactory and up to the mark and the work is within the acceptable and permissible limits of deviations as er relevant Code of Practice? '1 '1 l / ,r Page 2 of3 .I' ' " Sr. No. Parameters Yes/No Remarks 4 Whether remedial measures are undertaken to Yes Brickbat Waterproofing has been done on prevent dampness and leakages? If yes, provide terrace, balconies and bathrooms details 5 Whether safety precautions are undertaken during Yes Safety belts and Helmets provided construction activities for all tvoe of workers? 4. Miscellaneous Sr. No. Parameters Yes/No No 1 Whether third party quality inspection is being No carried out on site during/after completion of the works? If es rovide details. 2 Whether anti-termite treatment has been undertaken Yes for the soil? 3 Whether fire-fighting arrangements has been No undertaken under su ervision of fire consultant? 4 Whether proper signages have been installed on Yes site/com leted buildin as er re uirement? 5 Whether precautions are undertaken to avoid air Yes ollution durin construction? Please s eci . 6 Whether records of all test reports/results have been Yes proper1y kept in the prescribed formats and whether the same are available at site for viewing by allottees and to be handed over to the association of allottees? 7 Whether all relevant records including sanctioned Yes building plans, utility drawings, various test reports/results have been proper1y kept in the prescribed formats to be handed over to the association of allottees? 8 Any innovative/cost effective/green technology has No been used for improving quality/energy efficiency? Please s eci . ACASR-8i1UK AD Yours Faithfully B.Tech(C,v ) ME {Structural) Consultant Structural Engineer Reg.No STATE/R/2025/APU,17891 Signature of Engineer (Site Supervisor) Name: Er Akash Gaikwad Home Point Gaikwad Qualification (Not less than graduate) License No. (if any): STATE/R/2022/APU01364 Phone No: g42_.0gltOt>~ Place: &,~~, Agreed and accepted by Signature of Promoter Name: Renucorp Private Limited Date: Page3of3