V FORM.2A I See MahaRERA order no' of 20{81 ENGINEER,SGERTIFICATEFoRQUALITYASSURANGE (site suPervisor's certificate) (To be uPloaded quarterlY) To, Road, Amravati(Name & address of The Busvland Heiohts, chitra chowk. Jawahar Promoter), (Certificate no forthe q,arter enoing Fi Zfln -n I I and quality of construction and subject : certificate for quality-of materials used 6t euiloing(s)/ wings(s) of workmanship for in" wotit ot- eu",rdn; Heiqhte' 'No' g C: S' No'/C'.T S' No'/ Survey the Phase of the proiect situated ;ffie demarcated bv its No.lFinal plot no' zo. srreet No'.s6i'P'"'rtlrJuG-Eeollin Amlavati boundaries (latitude and longit'Oe ct"*r-t" the- NorthJawahar west of Division Boadto the south--*ot* *"-r,; th"E*t ghjlrd the admeasuring Amravati vilage Amravati tarukg MdA[niutn@P1N44601 f f ZSf sq.mtts. area being developed by HEIGHTSI [Promoter's NameBUSYLAND Reference:MahaRERARegistrationNumber-P50300016893 Sir, of supervision of this We Krishna Associates have undertaken an assignment realestate Proiect' 1. Our ResPonsibilitY: - per the out the work in accordance with the rlevelopment permission and as To carry bt work and to carry out material approved ptan anO sunmit certificate oi.up.t,iision anrl to ensure quality of work and testing in-situ o, inine authorized laboratory 1. Material Testinq :' in the checks on the basic materials' used l/we, have applied following mandatory construction. i' cement r---^^^ ^^"nr{nacc setting cattinn time' compresslv( : strength etc' It has been tested for its fineness, soundness, iete''ant ,SJ8'/NBC code' oras per industry as per lS code 3535:1986 or r. p"ioinei limits' permissible standards and its results are within the ii. Coarse aggregate - value as materials, clay ]r1119s, crushing value'.impact lt has been tested, for deleterious per rs 243a1rgas oi.i p..", o]l-":L"1",,';r;J rbiesrNec d;;;; per inousiry standards anditsresults,,"*itni''thepermissiblelimits. iii. Brickst blocks - per lS 5454:1978 absorption, crushing strength etc' as Thev have been tested for wate.r and its results are or a! oer other rerevant rs/8s/NBc #$;;J;;;ildrrtry'itanoaros witnin' Permissible limits' iv. ConcretelReady'mix Goncrete- per 15 456:2000 and for yario-ls.periods as its rt has been tested for compressive.strength cooe', inoustrv standards and rsBb/NLc ls 1 1ee or as p"r'oiiJ#i!r*tlimits' " i"i ;t;iit are witirin Permissible v. Steel for concrete- ;ffi J;;;;,'pe1rs'?9?::r::il^'Tfl;'l':l':l,"JX1ijr'i1:,$',""il::fJft: ["1.ffi:,ir,"u",1iiid:Fli:H'j-:'3;;n;i'i'.15;*d';;;;Gtinstnetcandits limits' Eriil;;; iriinln Permissible vi. Testing of Other materials pipes and crushed sand, froor. tires,. fixtures and {ittings' sand, other materiars rike "(ii;i ;i;. oui. an-*:?rJi ,r"o * tnir'prq.ct cohform torelevant sanitary fittings or as per standards'rliiio*n ty the rnolr.iw toi a particular material' rs/Bs/NBc code 2.WofKmaltnrrrrr'- 2. WorkmanshiP:- .,_..r.r^ "n.Wefufthef r/ we herebv certifv that work h1.i:":-?3::i:.:1'":1fL",i:'ti::[:: the work has. sausTacturv arI\r *'y.Jinili!{e,r:^r,#,:"}Hr,,:'"$:l;:1il[J::,-slJT' tnrt workmans.hip ?.t9 lTP^: tl"xi^,Hl'Jff Lrtitv permissible Jtiil'r. limits of devi p"r relevant code of been acceptable *itnin the practice. 3. Electrical Materials and workmanship: - installations wiring/connections/rift installation/other electrical works of a* the erectricar erectricar engineer and its records have been carried-out under .rtnoriiliir"girt"i"o l's/ B's/ National tffi;bv?nt has been ,rint"inJi. iii"-r"t"ri"rr-JJ"JEontorm standards' Building codes or as per indusfi 4. Structural engineer: - PromotershasengagedstructuralengineerEhreeiistructurals.Ahmedabad his supervision' this project has been done under The structural design of buirdings_in irv,;n i;aC f?t-F;d"tion in consultation with soil He has checked ti.,E ,o* report *tor" concrJt"-fiir1"sign has oeen oone as pe.r ls 10262:2009 consurtant. The formwork and cnecrs and certificates for ,fuii""or"' or as per other i"l"rjnt '-';;;' codes- I sAFET-i have been kept .Fritp"tfii; on STABILITY record. 5. Preservation of records: - Record of all test results of this project have properly kept in the prescribed formats and will be preserved at least up to the c liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of which were not conforming to the standard specifications and which were not Yours Faithfully, of Engineer (Site Supervisor) Name:Vikram K. Shadi License no.(if any)- M&l-12288 Phone no:9326688881 Place:Amravati.