Residential Signature valid FSI AREA BALCONY TERRACE VENT Other TOTAL Owner Name Postal Address Contact Number BUILDING FLOORS LIFT LIFTWELL DUCT COMM. RESI. IND. SPECIAL MEZZ. PROP. PROP. SHAFT Deduction FSIAREA CST, No 33, Plot No 16, Infront of Digitally signed by chidrawar sandip diliprao Abhyasika Hall,Prabhat Residential Ff SF TF Forth Fifth 0.00 1245.85 0.00 0.00 0.00 135.50 0.00 13.00 0.00 196.35 0.00 0.00 1049.50 Gopal Dattatray Mahajan 9823160497 Date: 2022.09.02 17:22:32 IST Colony,,Bhusawal,Bhusawal,Jalgaon-42 Residential Ground Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5201,Maharashtra Reason: Approved Drawing Plan Residential Total 0.00 1245.85 0.00 0.00 0.00 135.50 0.00 13.00 0.00 196.35 0.00 0.00 1049.50 Prakash Punjo Patil Bhusawal Location: Bhusawal Municipal Council Dilip Waman Patil Bhusawal FSI DETAILS Incentive FSI for Basic FSI Premium FSI TDR green building If Ancillary Area Ancillary Area Inclusive Housing 9 Index Total Drawing Value (on serial no 1) (on serial no 1) (on serial no 1) Applicable 60% of (2+3+4+5) 80% of (2+3+4+5) (20%) If Applicable ( on basic FSI) 9.1 Permissible Index 1.10 0.00 0.00 0.00 0.00 0.00 1.10 0.00 0.00 9.2 Existing Proforma I : Area Statement Parking Check As Per Multiplying Factor : 0.60 Comsumed 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 OWNERS:- 1. Area of plot (Minimum area of a, b, c to be Required Proposed Index Building N ame Status Car/Mini Bus Scooter Car/Mini Bus Scooter considered) or area of subplot with sanctioned layout No. 597.12 9.3 Balance Index to Total 6 0 6 0 OK S.NO. O.P.F.&P.NO. P.NO. PLACE 1.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Note- 6 Scooter and subplot No. Town Planner be Consume eq uals to 1 Satare Shivar T.S.No. II Ca r,proposed Date: 29/08/2022 9.4 Total Permissible composite parking=6 14/3B 39 1+2 At Bhusawal (a) As per ownership document (7/12, CTS extract) 597.12 PLine Area() 656.83 0.00 0.00 0.00 394.09 0.00 1050.92 0.00 0.00 AREA STATEMENTS SQ. M. (b) as per TILR or City Survey measurement sheet 597.12 9.5 Proposed P Line Parking Check (Tabl e 8B) Area (Should not 656.83 0.00 0.00 0.00 392.67 0.00 1049.50 0.00 1049.50 REQ. RATIO PRP. RATIO AREA OF PLOT 597.12 (c) as per Demarcated drawing area 597.14 Buildi ng Name USE NO.OF Tena/Area car Scoote r c ar Scooter exceed 9.4 ) Residential Residential 1 2 20 10.00 20.00 NORMAL F.S.I. 1.10 656.83 Tot al - - - - 10.00 20.00 ANCILLARY FSI 60% 394.41 LESS 9.6 Index Consumed 1.09 0.00 0.00 0.00 0.00 0.00 1.09 0.00 0.00 Visit ors parking(5%) - - - - 0.50 1.00 Tot al - - - - 10.50 21.00 TOTAL PERMISSIBLE BUILT UP AREA 1051.24 2.Area not in possession 0.00 GROUND FLOOR BUILT UP AREA FIRST FLOOR BUILT UP AREA 209.90 3. Entire area (1-2) 597.12 SECOND FLOOR BUILT UP AREA 209.90 4.Deductions for - 2.8 THIRD FLOOR BUILT UP AREA 209.90 FOURTH FLOOR BUILT UP AREA 209.90 (a) Proposed D.P./ D.P. Road widening Area /Service 0.00 Carpet Area Table FIVE FLOOR BUILT UP AREA 209.90 Road / Highway widening Enclosed Balcony Normal Balcony Building Name Floor Name Carpet name Tenement No Carpet Area Total Carpet Area TOTAL BUILT UP AREA 1049.50 Area Area (b) Any D.P. Reservation area 5F Residential Ff SF TF Forth Fifth 2bhk 5 34.0 1 0.00 0.00 34.01 0.00 2.750 Residential Ff SF TF Forth Fifth 2bhk 5 39 .03 2.64 0.00 41.67 Residential Ff SF TF Forth Fifth 2bhk 5 38 .88 2.64 0.00 41.52 (Total a+b) 0.00 Residential Ff SF TF Forth Fifth 2bhk 5 34.0 1 0.00 0.00 34.01 5.Balance area of plot (3-4) 597.12 6. Amenity Space 0.00 2.750 4F 2.6 2.6 (Applicable if (1) > 20000 sqmt - (Required -(a) Upto 20000 sqmt - Nil - WATER TANK (b) Above 20000 sqmt - (a) + 5 % of Total area 0.00 1.200 2.750 3F 7. Net Plot Area (5-6 ) 597.12 SLAB M.S.GATE 3.630 SCALE: 1 00 T:-0.25 8. Recreational Open Space - 2.330 R: -0.19 16.800 PARAPET WALL P.C.C.COPING (a) If area (6) is more than 4000 sqmt - 10 % of (6) is 1.050 V 0.00 2.8 SLAB 2F 0.100 BEAM CW_HT CW_WIDTH thk.BK.WALL required. 2.750 GL. Proposed___ .45 thk.STONE WALL. 0.00 2.84 (b) If area is less than 4000 sqmt -Check - BUILT-UP AREA CALCULATION P.C.C. STUDY - Ground Floor Residential V i) If it is full number like 1,2,125,419,etc. As per 7.12 SLAB COMPOUND WALL 2.750 1F 0.100 BEAM abstract or City Survey Number - No Recreational open - DETAIL BUILT UP AREA CALCULATION SCALE: 100 space is required FOR Ground Floor Residential 2.84 AREA NAME LENGTH WIDTH Area(Sq.M) ii) If it is subdivision like 1/2 ,2/5 , 125/1 419/1 etc.then BLOCK 2.80 2.60 7.28 SLAB recreational open space is required. - 0F 0.100 V 2.750 BLOCK AREA TOTAL =7.28Sq.M BEAM TOTAL Deduction =0.00Sq.M (A) 10 % Subject to minimum 200 sqmt 0.00 G.I. OF Plinth Net BuiltUp Area =7.28 Sq.M 14.70 2.84 Proposed ______________ 0.300 0.00 SECTION VIEW - Residential (B) Exemption to leave open space subject to availing SLAB - 0.100 V 17.100 BEAM basic F.S.I of 75 % (C) Exemption to leave open space subject to payment BUILT UP AREA CALCULATION 2.84 of 10 % land value of land at (7) as per annual - 2.2 FOR Ground Floor Residential statement of rate. SLAB V AREA NAME LENGTH WIDTH Area(Sq.M) 0.100 ← ← ← 6.10 M.W. T.P.S. ROAD → → → BEAM BLOCK 2.20 1.50 3.30 Certificate of Area: BLOCK AREA TOTAL =3.30Sq.M 2.84 Certified that the plot under reference was surveyed by me on TOTAL Deduction =0.00Sq.M NORMAL HEIGHT TOTAL HEIGHT SLAB V 2022-03-03 and the dimensions of sides etc. of plot stated onplan Net BuiltUp Area =3.30 Sq.M 0.100 SOAK 18.50 10.20 are as measured on site and the area so worked out tallies with the PIT 1.5 1.5 area stated in document of Ownership/ T.P. Scheme Records/Land 2.750 RMWH BUILT UP AREA CALCULATION Records Department/City Survey records. G.L. Signature FOR Ff SF TF Forth Fifth Residential R. C.C.FOUN. 4.737 Area(Sq.M) 6.480 AREA NAME LENGTH WIDTH (Name of Architect/ Licensed Engineer/ Supervisor.) drainage line BLOCK 25.41 12.22 249.17 Owner's Declaration - 2.2 BLOCK AREA TOTAL =249.17Sq.M I/We undersigned hereby confirm that I/We would abide by plans Duct2 - - 16.40 2.560 5.100 2.560 BUILT-UP AREA CALCULATION 0.100 2.460 0.100 2.400 0.100 2.400 0.100 2.460 0.100 approved by Authority / Collector. I/We would execute the structure Duct1 - - 22.87 Ground Floor Residential TOTAL Deduction =39.27Sq.M as per approved plans. Also I/We would execute the work under Net BuiltUp Area =209.90 Sq.M BAL. BAL. supervision of proper technical person so as to ensure the quality 1.35X1.0 1.35X1.0 2.7 W W 3.011 and safety at the work site. D D 1.2 1.2 1 1 1.600 BEDRM. BEDRM. 1.600 1.600 2.40X3.75 2.40X3.75 Owner (s) name and signature W W UG 2.56 2.56 SCHEDULE OF OPENING: 0.100 TANK 1.6 1.6 BEDRM. BEDRM. Architect/ Licensed Engineer/ Supervisor name and signature PLOT NO. 4 BLD NAME NAME LENGTH HEIGHT NOS. 2.46X2.81 2.46X2.81 Residential V 0.60 0.60 6 W W 2.810 Job No. Residential V 0.60 0.90 2 4.050 D D1 D1 D 4.050 Residential W 1.20 1.20 22 D TOI LET TOILET D 4.05 4.05 A A 1.40X1.08 1.40X1.08 0.100 TOILET TOILET 1 1 V 1.46X1.04 V V D1 1.46X1.04 V 1.040 D1 SCHEDULE OF OPENING: 4.82X2.20 0.100 COMP KITCHEN KITCHEN BLD NAME NAME LENGTH HEIGHT NOS. 2.50X1.50 2.50X1.50 W COMP W 1.500 OPEN TO Residential D 0.87 2.10 1 SKY DUCT D D Residential D1 0.75 2.10 5 0.100 101 102 W 4.2 4.2 4.200 4.200 Residential D 1.00 2.10 7 W LIVING 201 202 LIVING 34.40 3.75X2.40 301 302 3.75X2.40 Duct2 2.400 P.NO. Residential D 0.90 2.10 5 401 2.32X2.50 402 BALCONY 4.20X1.00 D SEPTIK BALCONY 4.20X1.00 502 D F.P. NO. 501 TANK 1+2 D 3.75 1 3.750 0.100 35.40 UP V B D UP V B 2.4 2.4 1 2.600 2.400 2.400 2.400 MANHOLE LIFT LIFT FREE B OARD 18000 2.00X1.30 1.500 2.00X1.30 Postal Address : CST, No 33, P SUM P WEL L LITRES CAPACITY. 2.800 0.10024.410 lot No 16, Infront of Abhyasik 2.75 2.75 2.128 D D OUTLET D LIVING 104 D 103 LIVING INLET BAFFLE 3.75X2.40 204 203 3.75X2.40 BK.WALL 304 2.400 303 DESCRIPTION OF PROJECT : 2.32X1.40 PARKING AREA 1 1 W 404 403 W P.C.C. SECTION THROUGH 1.35 1.35 505 503 Type of Proposal : Residential BALCONY 2.75X1.00 D BALCONY 2.75X1.00 D 0.100 CROSS SECTION U. WATER TANK. COMP COMP KITCHEN KITCHEN BUILDING ON CTS. NO./SURVEY NO.- 14 6.500 W 2.40X1.50 2.40X1.50 6.500 1.500 PARKING AREA W 2.4 2.4 OPEN TO Duct1 VENT PIPE .23 thk.BK.WALL D D 0.100 SKY DUCT 5.02X3.51 MANHOLE STUDYRM. STUDYRM. SITE ADDRESS : 1 3.40X2.20 3.40X2.20 W 2.200 ENCLOSED BAL. W ENCLOSED BAL. S.no 14/3B F.p no 39 Satare Shivar Tp 2 ST_WID OUTLET TOILET TOI LET 0.100 PLOT NO. 3 4.28 4.28 TOI LET D1 1.50X1.00 TOILET 3.000 Bhusawal 1.50X1.00 V1.82X1.10 V D1 PLAN OF UNDERGROUND V 1.40X1.08 1.40X1.08 V 1.080 D1 D1 INLET ST_LEN WATER STORAGE TANK COMP COMP D D 0.100 SEPTIC TANK DETAIL SCALE: 100 BEDRM. BEDRM. BEDRM. BEDRM. Name Of Engineer : Vidya Mahajan 2.5 2.5 SCALE: 100 4.280 4.280 2.40X3.00 2.46X3.75 2.46X3.75 2.40X3.00 1.38 1.38 3.000 Residential 3.045 W ADDRESS OF OFFICE W 5.22 OFFICE : D 0.100 Bhusawal W D W W W 4.604 4.459 1.380 1.380 1.380 4.459 BALCONY 2.61X1.00 BUILT-UP AREA CALCULATION 1.000 0.100 2.400 0.100 2.460 0.100 2.460 0.100 2.400 0.100 1.000 Project Details 1.000 2.500 5.220 2.500 1.000 Ff SF TF Forth Fifth Residential WATER STORAGE REQUIREMENT OWNERS SIGN: TECHNICAL PERSON SIGN Building Type - Building Development 12.220 OVER HEAD WATER TANK REQUIRED Verified by applicant Zone Type - Residential Zone Signature valid 20 TENEMENT = 100 PERSON X 135.00 .Ltr →→→ Digitally signed by VIDYA GOPAL MAHAJAN Location - Non-Congested Date: 2022.09.02 17:19:28 IST M.W. T.P.S.ROAD LEGENDS: 13500.00Ltr ← ← ← 6.10 Ward No - Reason: Technical Person DSC PLOT BOUNDRY SHOWN WHITE Location: Bhusawal Municipal ouncil Plot No. - 1+2 PROPOSED WORK SHOWN RED Ground Floor Cts No./Servey No. - 14 DRAINAGE LINE SHOWN YELLOW LIGHT Sheet No. - 1 Ff SF TF Forth Fifth SITE PLAN N WATER LINE SHOWN BLUE DOTTED 13500.00 Ltr. X 1.50=20250.00 Ltr SCALE 1:100 Date: 08/06/22 Zone Number: (SCALE:-1:100) PROPOSED-O.H.W.T = 0.00 .Ltr ENCLOSED BAL SHOWN BROWN Ward Name : UGR Prop:0.00 TERRACE SHOWN DARK YELLOW Prorata Value : 0.00 OPEN BAL SHOWN BRAWN Residential JOB No. CAJBC-22-24373 EXSTING SHOWN BLUE HATCHED