GOLAIT& ASSOCIATES Er. Vikas Golait BE. (CvIL). PGOBM, AIE 10, 'SATYABHAMA , Reg. No.: RA/007858/2 SAMAJ EKTA SOCIETY Mobile: 9823112656 NEW SOMALWADA, NAGPUR -05 E-mail golaitvl@gmail.com (Behind Hotel Pride) FORM-2A See MahaRERA Order No. of 2018| Engineer's Certificate for Quality Assurance ARCHITECT (Site Supervisor's Certificate) To, RSV Realities, Wardha Quality Assuranee Certificate CVL (Certificate No. QAC/01/19-20 for the quarter ending March 2021) ENGINEER Subject: Certificate for quality of materials used and quality of construction and workmanship for the Work of Vastuvishwa Apartment Bapatwadi No. of Building(s) / One of the project situated on the plot bearing C.S.No./C.T.S. No./Survey No./Final Plot No. 5 & 6, Survey No. 15/2 (Revised) demarcated by its boundaries (latitude and longitude of the end points) to the North Layout Plots No. 12 & 13 to the South 18 M Wide Road to the East Plot No. 4 of the Layout to the West of Division Plot No. 7 of the layout T.C. 19, within M.C. Limits of Wardha Taluka Wardha District Wardha Pin 442001 admeasuring 607.50 sq.mtrs. area being developed by INTERIOR [Promoter's Name RSV Realities, Wardha] DESIGNING Reference MahaRERA Registration Number - P -50400012080 Sir, We Golait & Associates, through myself, Er. Vikas Golait have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and LAYOUT WORK 1 Material Testing:- (FARM l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant IS/85/NBC code, or as per industry standards and its resuls are within the permissible limits. ii. Coarse aggregate- It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per Is Govt. 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are APPROVED VALUER within the permissible limits. L G0L TRUNKEY PROJECT * NIT NM namti gar GOLAIT& ASSOCIATES Er. Vikas Golait B.E. (CVIL), PGDBM, AIE 10, 'SATYABHAMA, Reg.No.:RA/007858/12 SAMAJ EKTA SOCIETY Mobile 9823112656 NEW SOMALWADA, NAGPUR 05 E-mail golaitvi@gmail.com (Behind Hotel Pride) iii. Bricks/ blocks - or as per other They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 relevant IS/85/NBC code or as per industry standards and its results are within permissible limits ARCHITECT iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and IS 1 199 or as per other relevant 1S/BS/NBC codes, as per industry standards and its results are within permissible limits. Steel for c o n c r e t e - . It has been tested as per 1S 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. CVL Testing of Other materials - vi. ENGINEER and sanitary fittings etc. Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes relevant IS/BS/NBC code or as per standards laid (List out all items) used in this project conform to down by the Industry for a particular material. 2. Workmanship: that out under our supervision. We further certify I/we hereby certify that work has been carried and the work has been acceptable within the mark workmanship and quality is satisfactory and up to the permissible limits of deviations as per relevant code of practice. NTERIOR 3. Electrical Materials and workmanship: DESIGNING installation/other electrical installations have been Works of all the electrical wiring/connections/lift maintained. The electrical engineer and its records has been carried out under authorized/registered standards. B.S/ National Building codes or as per industry materials used conform to the relevant I.S/ 4. Structural engineer: RA/007858/12 Vikas L. Golait having Licenses no. Promoters has engaged structural engineer Mr. 9823112656. having Office at Nagpur cell no He has checked in this project has been done under his supervision. The structural design of buildings consultant. The formwork and for foundation in consultation with soil the soil report before laying PCC as per other relevant codes as applicable. LAYOUT concrete mix design has been done as per IS 10262:2009 or have been kept on record. certificates for STABILITY and SAFETY WORK His periodic checks and (FARM) Preservation of records: 5. be in the prescribed formats and will Record of all test results of this project have been properly kept as required by any other provision of at least up to the defect liability period or for the period preserved law. to the standard other item of work which were not conforming 6. Please specify materials or any were not rejected. specifications and which Govt. APPROVED Yours Faith fully, VALUER Supervisor) Signature of Engineer (Site :Golait& Associates Name RA/007858/12 GUL TRUNKEY License no.(if any) Phone no. Place :9823112656 Wardha * SN wi004 AlT_ PROJECT 3NM a Nasar namt