FORM-2A See MahaRERA order no. of2018] ENGINEER'S CERTIFICATE FOR QUAITY ASSURANCE (slte supervisor's certiflcate) To, The Raadhe Builder, Raam Laxman Sankul, Shop No.20 Amravati, Quality Assurance Certificate 20 (Certificate no_ for the quarter ending_ ") ec 2o Subject:Certificate for quality of materials used and quality of Construction and workmanship for the Work of No. of Building(s)/ Wings(s) of the Phase of the project situated on the plot bearing C. S. No./C.T.S. No./ demarcated by its boundaries (latitude and Survey No./Final plot no. 123 longitude of the end points) Survey No.2 to the North,Sai Nagar to Akoli Road 4 to the South, Plot No. 4 to the East Akoli Gaothan to the West of District Amravati PIN-444607admeasuring 688 sq.mtrs. area being developed by Raadhe Builder [Radhe Residency] Reference: MahaRERA Registration Number- P50300013532 Sir, Ihave undertaken an assignment of supervision of this real estate project. 1. Our Responsibility:- To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testing we, have applied following mandatory checks on the basic materials, used in the construction. . Cement has ben tested for its fineness, soundness, setting time, compressive strength etc. as per15 code 3535:1986 or as per other relevant IS/85/NBC code, or as per industry standards and results are within the permissible limits. i. Coarse aggregate- Enas been tested, for deleterious materials, clay lumps, crushing value, impact value as per id 43011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. Hi, Brlcka/ blocks- They have been tested for water absorption, crushing strength etc. as per IS 5454:1978 or as per other relevant S/45/NBC code or aS per industry standards and permisalble limits its results are within w. Concrete/Ready mlx Concrete t has been tosted for or 8s per other compressive strength for varlous periods as per 15 456:2000 and IS 1199 relevant 1S/3S/NBC codes, as permissihle limits. per Industry standards and its results are within v. Steel for concrete I has been tested as per 1S 2062:2011 or as per other industry standards for tenslle relevant IS/BS/NBC code or as per within permisslble limits strength, elongation and gauge length etc. and its results are . Testing of Other materlals Other materlals like sand, crushed floor tles, fixtures and fittings etc. (List out all items) used insand, this {ittlngs, pipes and sanitary standards laid down by the project conform to relevant Industry for a particular materlal. IS/BS/NBC code or as per 2. Workmanshlp: / we hereby certify that work has that been carrled out under our wor krmanshlp and quality is satisfactory and supervislon. We further certify accptable within the permisslble lImits of up to the mark and the work has been devlatlons as per relevant code of 3. Electrical Materlals and practice. workmanshlp: Works of all the electrical been carrled out under wirlng/connections/litt installation/other electrical installations have authorlzed/reglstered maintained. The matorlals used electrical englneer and its records conform to the relevant I.S/ has per industry standards. or B.S/ National Building codes been as 4. Structural englneer:- Promoters has engaged structural engineer Mr.-havlng Cell no Licenses no.--having office no The structural design bulldings In this project has been checked the soll report belore laylng PCC for foundatlon done under his He has supervision. In consultation with soil The formwork and concrete mix consultant deslgn has been done as per Is 10262:2009 or as relevant codes as applcable, His per other been kept on perlodic checks and certiicates for STABUIIY and SAFE IY have rocord 5. Preservation of records: - formats ana Record of all test results of this proiect have been properly kept in the prescribed for the period as required by any wIll be preserved at least up to the defect liability period or other provision of law not conforming to the item of work which were 6. Please specify materials or any other standard specifications and which were not rejeded. ayvart ivit Yours Faithfully, Ofnvin Nae Signature of Engineer (Site Supervisor) Name: License no.(if any)-- Phone no. Place:-.