Anurog S. Agrowol B.E. (Civil), AMIE, FIV CiYil Engineer & Contractor FORm-2A 1360 Reguletion 3A.l ENGINEERS'S CERTIFICATE FOR QUALITY ASSURANCE (Site Sup€rvlso/s C,6rtncat6) (To bo submitt d at th€ ond of Finandsl Year) Date: To, Th6 BAL .rl BUILDCON Akola (M Corp.), Akola, Al(ola, 444{Dl Qualfi Assurance Certlf, cato (Ce mcate No. ......................br lhe Year Ending .......................) Subject : Corttf,cato for quality of materials u86d and quality of Constuc-don and $orkmanship of tho wotk of DWARXA having MahaRERA Rogistraton Number P5OlqpS{008 b€ing dovslopod by BALAII BUILDCOX Sir, l/We ...................... har/6 undertaken an assignment of sup€n lslon of thi8 rsal ostate proj€ci Our R..pon lblltty To carry out the urod( in eccordanco with th6 de€lop.nont p€rmissbn and as por lfio approlrod plan, b submit cedficato of sup€rvision ol wod(, to carry o(d mabrial teoling ln€lhl or in an authortsod laboratory e3 per provailing and applicabl€ standards, b ensure quality of work and nDd(manship as per pr€acrlbed spodfcetions, 8nd aE por NBC end / or o&er r€l€vant codo of pradlo6. The dotails of the quality ar8 as follorvs : 1. St uctural D..lgn, Steblllty and To.tlng Sr. No. Perameiors Yo.rNo Romark3 I Whelher soil invostigations of tho sito has besn Y6s conducted b€foro th6 struclural dasign and soil paramoters havo be€n accountod for in lhe struotural dosion/drawinos? 2 Whethor Structural Engineer has b€sn appointsd for Yes Namo: Ritosh J. Laddha the proj6ct? Liconse No: Stato/R/202t4PU17906 Mobile: 0721266166 E-mail: laddharit*h@omall.com 3 Whethor the insp€ction registers, site ord€r book Yes and quality control tost r6gist6rs are malntainod at tho sito propody and endor8ed by the Engine€r-in- Chame? 4 Whethor testing facilities to ched( quality of matorial Yes is available at site? H-11, Mhada Colony, Opp. Kidzee ptbggl6 Ram Nagat AKOLA - 444 005 (M.S.) Mobile : 94231 44398 o E:mail: anurag.consultant@gmail.com Sr. No. Pararnebrs Yes/No Remarks 5 WhetlEr th6 stafuary provisiorB br disastar Yes resistanca/eartquaks resistar d€x*f h6rc been incorporated, specially in cas€ of multi$.B!/€d 6 Has suitable cognizanca boen taken on demarcated Yes flood lines and appropdiate pr€cautirns tak6n for ur" floodins mnsidsdns tocat fiBtm;m"";b 2. lnput ilaterlals Sr, No. Parameters Ye3/t{o Remarks 1 Whether the following building materials confirm to Yes relevant IS,/BS/NBC Cod€, or as per lndusty Standards? lf yes. orovide detaild: (a) Cem€nt, concreJ6 and @ars€ aqgrcqata Yes (b) Stsel and its allovs Yss (c) Electrical wire. fittinos and accessodes Yes (d) Plumbing and san'rtary fittinqs Yes 2 Whether regular tests of materials and constuc{ion Yos products are being dons fiorn accr€dited labs also? lf yes, details of sucfi hbs 3 \rvhether manufaclurer t6st @rtifcate for cement, Yes slesl, pip6s etc. have been obtained and whethei suoolv rocolds are b6ino maintain€d? 4 Whsther suitablB wator is b€ing used for Yos consbuction? (i) What is the seurce of watep Yes (ii) Has water b€en tested and aoorDved bv Yes Engine€r-in-Charqe before consLirction?' (iii) Has wat€r been tested subs€quen0y as per Yes lgquirement? 3. Quality of Workmamhlp Sr. No. Parameters Y63/llo Remarks 'l \ivhether works of all ihe electrical Yes wiring/connGdions/lifi instaflation/oher electrical installations have boen canied oul under authorized/rsgisterBd elecfical enqin€sr and lyhethef recods of the same has b€en meintelned? 2 Whethor all related works of plumbing & sanitary Yes induding installation of water supply Eystems, ' drarnage syst9ms, s€wage systems, sinks, toilets etc. have b€en canied out undar authorized/registered plumb€rs/sanitary contrac{ors and whether records of the same has 6€en maintained? Whether all th€ work is b€ing canied out under Yes supervasion of experienced and skilled professional? Funher, whether ths workmanshio and'oualitv is satisfadory and up to the mart and ttre ri,o*is within the acceptablo and oermissible limits of deviations as Der relevant Code of Practice? Pag6 2 of3 Sr. No. ParametoG Yes/No Remarks 4 Whether remedial measures als unmksn to Yes prevsnt dampness and loakag€s? lf yos, p.ovile d€tails 5 Whether safety pr€caulions aIs undertakon &rtitrg Yes construc;tion aclivitiss for all tvDo of workeG? 4. ,{iscollaneous Sr. No. Parametors Yes/No No I \wheth6r third psrty quality inspoctio{r is treing Yes canied out on site during/anor completion of -the works? lf yes, orovido dotails. 2 Whather anti-temite tEatmor has been undertaken Yes for the soil? Vvhether firBfighting anangements has b€en Yes undertaken under suD€rvision of fire consultant? 4 Whether proper signagos have b€€n installed on Yes site/completed buildinq as Dor reouir€ment? 5 Whether prBcautions are undertaken to avoid air Yes pollution durinq consEuction? Pleasa sD€cifi/- 6 Whether rscords of all t€st rBporhi/rBsults hav6 been Yeg pmp€rly kept in lhe prsscribsd formats and Mtethsr tho same aI€ available at site for vior|im bv allottees and to b€ handed over to the a-ssdciation of allottees? 7 Wh€lher all relevant recods including sanctioned Yes building plans, utility drawings, variouis test reports/results have bsen properly kept in the prescribed formats to be handed o/er to the qllq,qiation of allottees? I Any innovative/cost effsctive/green tochnology has Yos quali-ty/onersy emd;icy? Bfrj::Y"3[,.,r."ins Yours Fa Signatur6 of Enginoer (Site Supervisor) Name: Anurag Shriram Agrawal Quamcabn (Not lsss than graduate) Liconso No. (tf any): AMC/14 Phono No: Place: Agre€d and accepted b Signature of Promoter Name: BALAll BUILDCON Dat6: Peg. 3 ot3