Anurag S. Aqrawal B.E. (Civil), AMIE, FIV Civil Engineer & Contractor FORM-2A ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE Site Supervisor 's certificate] To, M/s SS Enterprises Gorakshan Road Akola. Quality Assurance Certificate ICertificate No.03 for the Quarter ending_June 2020]1 of Construction and Subject: Certificate for quality of materials used and quality Of building of the Only phase of the workmanship for the work of Building "IT Square" for 1 No. No. 10+11, Nazul Plot No. 6/1,7/1, 12, 13, project situated on the plot No. 59 & 60, Survey demarcated by its boundaries [ latitude and longitude 14 /49 & 14/50, Nazul Sheet No. 68/80 24m wide layout Road to the South, Layout Plot of the end points ] Servie Lane to the North, No 61 to the East, 15 mtr layout Road to the West of Mauje : Umerkhed, taluka Akola District 1916.67 sq.mtrs. area being developed by M/s SS Enterprises Akola PIN 444001 admeasuring Refernce: Maha RERA Registration Number-P 50100023518 Sir, of this real estate project. undertaken an assignment of supervision I Anurag Agrawal have Our Responsibility accordance with the development permission and as per the work in To carry out the material certificate of supervision of work and to carry out approved plan and submit laboratory and to ensure quality of work and the authorizd testing in-situ or in 1, Shri Mangal Apartment, Ranpise Nagar, AKOLA 444 005 (M.S.) Mobile 94231 44398 E-mail: anurag.consultant@gmail.com KO A workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. Material Testing /We,have applied following mandatory checks on the basic materials used in the construction. Cement It has been tested for its fineness, soundness, setting time, compressive strength etc. As per IS code 3535: 1986 or as per other relevant IS BS/ NBC code,or as par industry standards and its results are within the permissible limits. Coarse aggregate It has been tested for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/ NBC code or as per industry standards and its results are within the permissible limits. Bricks /blocks- IS 5454: They have been tasted for water absorption, crushing strength etc.as per 1978 or as per other Relevant IS/ BS/ NBS/ code as per industry standards and its results are within permissible limits. Concrete / Ready-mix concrete It has been tested for compressive strength for various periods as per IS 456:2000 and IS 1199 or as per industry standards and its results are within permissiblelimits. Steel for concrete It has been tested as per IS 2062:2011or as per other relevant IS/ BS/ NBC/ Code or etc,and its as per indudtry standars for tensile Strengh, elongation and gauge length results are within permissible limits. {s7Reg.No.. AMC/14/ 20 AKO Testing of Other materlals Other materials like sand ,crushed sand, floor tiles, fixtures and fitting, pipes and sanitary fittings etc used in this project conform to relevant IS/BS/NBC Code or a per standards ald down by the industry for a particular materlal 2. Workmanship I/We hereby certify that work has been carried out under our supervision, We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and Workmanship: Work of all the electrical wiring/ connections/other electrical installations have been carried out under authorlzed /registered electrical engineer and its records has been maintained. The materials used conform to the relevant 1.5/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: Promoters has engaged structural engineer Dr. Abhay Patil of PATIL ASSOCIATES having Licenses no CABYC/R/2021/APL/00307_having office no 9822461251 cell no 9822461251 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per IS 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. Reg. No. AMC/14/ 2017 Va AO 5. Preservation of records: Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were rejected- None ofthe material were rejected and none of the work were not confirming to standard specificiations Yours Faithfully, Anurág Shriám Agrawal iran Reg. No. (B.E. Civil,AMIE, FIV) EAMC/14/) Regd No.: AMC/14/2017 2017 H11, Mhada Colony, Near Kidzee School, AKOL Ramnagar, Akola -444001 Mob. 94231 44398 Email anurag.consultant@gmail.com