Anurag S. Agrawal B.E. (Civil), AMIE, FIV Civil Engineer& Contractor FORM-2A ENGINEER'S CERTIFICATE FOR QUAITY ASSURANCE Site Supervisor 's certificate] To, M/sSS Enterprises Gorakshan Road Akola. Quality Assurance Certificate Certificate No.02 for the Quarter ending March 20201 Construction and Subject: Certificate for quality of materials used and quality of the Only phase of the workmanship for the work of Building "IT Square" for 1 No. Of building of 6/1, Plot No. 7/1,12, 13, project situated on the plot No. 59 & 60, Survey No. 10411, Nazul boundaries [ latitude and longitude 14 /49 & 14/50, Nazul Sheet No. 68/80 demarcated by its Road to the South, Layout Plot of the end points ] Servie Lane to the North, 24m wide layout No 61 to the East, 15 mtr layout Road tothe West of Mauje : Umerkhed, taluka Akola District Akola PIN 444001 admeasuring 1916.67 sq.mtrs. area being developed by M/s S S Enterprises Refernce: Maha RERA Registration Number-P 50100023518 Sir, of supervision of this real estate project. IAnurag Agrawal have undertaken an assignment Our Responsibility and as per the To carry out the work in accordance with the development permission work and to carry out material approved plan and submit certificate of supervision of testing in-situ or in the authorized laboratory and to ensure quality ofwork and FORM-2A 1, Shri Mangal Apartment, Ranpise Nagar, AKOLA 444 005 (M.S.) Mobile: 94231 44398 E-mail: anurag.consultant@gmail.com AKOA workmanship as per prescribed specifications, and as per NBC and or other relevant code of practice. Material Testing /We,have applied following mandatorychecks on the basic materials used in the construction. Cement It has been tested for its fineness, soundness, setting time, compressive strength etc. As per IS code 3535: 1986 or as per other relevant IS BS/ NBC code,or as par industry standards and its results are within the permissible limits. Coarse aggregate It has been tested for deleterious materials, clay lumps, crushing value, impact value as per IS 2430:1986 or as per other relevant IS/BS/ NBC code or as per industry limits. standards and its results are within the permissible Bricks /blocks- IS 5454: water absorption, crushing strength etc.as per They have been tasted for its 1978 or as per other Relevant IS/ BS/ NBS/ code as per industry standards and limits. results are within permissible Concrete / Ready -mix concrete IS 456:2000 It has been tested for compressive strength for various periods as per limits. standards and its results are within permissible and IS 1199 or as per industry Steel for concrete- relevant IS/ BS/ NBC/ Code or IS 2062:2011or as per other It has been tested as per etc,and its standars for tensile Strengh, elongation and gauge length as per indudtry limits. results are within permissible shri Reg. No.: B A M C / 1 4 / 2017 AKO Testing of Other materials Other materials like sand ,crushed sand, floor tiles, fixtures and fitting, pipes and sanitary fittings etc used in this project conform to relevant IS/BS/NBC Code or as per standards laid down by the industry for a particular material. 2. Workmanship I/We hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3.Electrical Materials and Workmanship: Work of all the electrical wiring/ connections/other electrical installations have been carried out under authorized /registered electrical engineer and its records has been maintained. The materials used conform to the relevant 1.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: Promoters has engaged structural engineer Dr. Abhay Patil of PATIL ASSOCIATES having Licenses no CABYC/R/2021/APL/00307_having office no 9822461251 cell no 9822461251. The structural design of buildings in this project has been done under his supervision . He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per IS 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. Reg. No. AMC/14/ 2017 5. Preservation of records Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were rejected-None of the material were rejected and none of the work were not confirming to standard specificiations wvn Yours Faithfully, rira Anurag Shrikám Agrawal (B.E. Civil,AMIE, FIV) Reg. No AMC/14/ Regd No.: AMC/14/2017 201 H11, Mhada Colony, Near Kidzee School, AKO Ramnagar, Akola - 444001 Mob.:-94231 44398 Email anurag.comsultant@gmail.com