FOIlM-2A I See MahaRlrRA orcler no. of 2018] ENGINEER'S CERTIFICATE F-OR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, Asha Builders & Developers Project : shricharan hieghts . Akola Oualitv Assu rance Certificate (Certificat. no ..S)l .lI:-.L.........fbr the quarter ending ..J*+:* :-..k.b...1' Subject : Certiflcate fbr quality of materials used and quality of Construction and workmanship tbr the Work of 1 No. of Building(s)/ 1 Wings(s) of the first Phase of the proiect situated on the plot bearing C. S.No./C.T.S. No./ Survey No 53/A ./Final plot no. 22 demarcated by its boundaries (latitude and longitude of the end points) 60 ft layout road to the North Remaining part of plot no 22 of Mr Govindabhau Pachurkar to the South Layout road to the East Dr Sudhir Lakhdive plot __________ to the West of Division NAP 34 urnri pra village Urnri taluka Akola District Akola PIN 444001 admeasuring3Tg sq.rntrs. area being developed by Asha Builders and Developers Reference: MahaRERA Registration Nurnber- P50100009L61, Sir. I/ We Abhileet Puri_ have underlaken an assignrnent of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development perrnission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material T'esting :- I/we. have applied following mandatory checks on the basic rnaterials. used in the construction. i. Cernent- It has been tested for its flneness. soundness. setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant ls/85NBC code, or as per industry standards and its results are within the permissible limits. ii. coarse aggregate - It has been tested, fbr deleterious materials, clay lumps, crushing value. irnpact value as per ls 24301 1986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the perrlissible lirnits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant IS/854{BC code or as per industry standards and its results are within permissible limits. iv. concrete/Ready-rnix concrete- It has been tested for compressive strength fbr various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes. as per industry standards and its results are within permissible limits. v. Steel tbr concrete- It has been tested as per lS 2062:201 1 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within pennissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and {ittings. pipes and sanitary fittings etc. (List out all items) used in this proiect confom to relevant IS/BSA{BC code or as per standards laid down by the lndustry lbr a particular material. 2. Workmanship:- I/ we hereby certify that work has been carried out under our superyision. We further certifiz that workrnanship and quality is satisfactory and up to the mark and the work has been acceptable within the pennissible lirnits of deviations as per relevant code of practice. 3. Electrical Materials and u,orkmanship: - works of all the electrical wiring/connections/lift installation/other electrical installations have been carrled out under authorized/registered electrical engineer and its records has been maintained. The rnaterials used confbrm to the relevant l.S/ B.s/ National Building codes or as per industry standards. 4. Structuidl engineer: - Promoters has engaged structural engineer Mr. Vipul Neerai Khosla. having l-icenses no. DDMCO/ Rt 2021 /AP L/0 040 I having offlce no. 8983735850 Cell no. 8983735850 / The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITy and SAFETy have been kept on record. 5. Preservation of records: -- Record of all test results of this project have been properly kept in the prescribed fbnnats and will be preserved at least up to the def-ect liability period or for the period as required by any other provision of law 6. Please specify rnaterials or any other itern of work which were not confonning to the standard specifications and which were not receded. ffii;it s. Fur! BE(Civil), ME(C.M) Akola 8452829406 Yours Faithfully, Signature of Engineer (Site Supervisor) Name Abhiiit Sanjay Puri License no.fif any ] Phone no . 8452829406 Place :- Akola