l FORM-2A I See MahaRERA order no. of 2018] ENGINEER,S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To DaIe:O7/O7/2O2L Sai Krushna Associates, 56, Shivram Nagar, Jalgaon-425001. Qualitv Assurance Certificate (Certificate noP499OOO28510 for the quarter ending 3OthJune 2O2Ll Subject :Certificate for quality of materials used and quality of Construction and workmanship for the Work of One Building(s)/ Wing(s) situated on the Plot bearing C.N. No / CTS No. / Survey no./Gat No. 182/2 Final Plot no.l3+1413 demarcated by its boundaries (latitude and longitude of the end points) Adj.P.No. 15 to the North, Adj.P.No. 12 to the South, 30 meter wide road to the East, Adj.P.No. 13+1412 & l3+I413 to the West of at Savkheda Bk Shivar, Taluka/District Jalgaon PIN 425001 admeasuring 525.00sq.mts. Area being developed by Sai Krushna Associates. Reference: MahaRERA Registration Number- P49900028510 Sir, l/ WeHEMANT JAGNNATH NYATI have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. MaterialTestine :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lS/85/NBC code, or as per industry standards and its results are within the permissible limits. It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant lS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 455:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- ft has been tested as per lS 2052:2OLL or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer Mr.Hemant Nyati having Licenses no. Lic No. l6having cell no 9422279876 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls L0262:2O09 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFEW havebeen kept record. 5. Preservation of records:- Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 5. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejeded. Yours Faithfully, f{HSf Ai.'i''ir t. rl.'y A'TI Jatgaon Cify l,iunrcipill fi ,)r00rail;n Signature of Engineer (Site Supervisor) ENGINEHFI t ltf o.lS Name: Hemant J. Nyati 7,POl_At,J f) fj TF{, IA i fiA.r)N License no.16 i.-1 rt t,.':i 4 7_ l ] 7 ;il tt r+ Phone no.9422279876 Place: Jalgaon '