FORM-2A [ See MAHARERA order no. of 2018] ENGINEER’S CERTIFICATE FOR QUALITY ASSURANCE To, The RAKA CONSTRUCTION SHAKUN ESTATE, S-196, Mahesh Nagar, Bhusawal Dist. Jalgaon. Pin-425201 Quality Assurance Certificate (Certificate no________ for the quarter ending________) Subject: Certificate of Percentage of Completion of Construction Work of the Building of the Project [RERA – Application done] situated on the Plot bearing City Survey No. 196/2B/1TO7 Plot no. 93 demarcated by its boundaries (latitude and longitude of the end points) PLOT NO. 196/2A to the North, 9 mtr wide road to the South, plot no.94 to the East 15.00 mtr wide road, 10 mtr wide wanjola road to the West of Division Nasik Village Bhusawal Taluka Bhusawal District Jalgaon PIN 425201 admeasuring 252.85 sq. mts. Area being developed by RAKA Construction, Bhusawal. Ref: MAHARERA Registration No. P49900026363. Sir, I Sachin Arun Patil have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: – To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material Testing:- I have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per IS code 3535:1986 or as per other relevant lS/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate – It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks – They have been tested for water absorption, crushing strength etc. as per lS 5454:1978 or as per other relevant lS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- It has been tested as per IS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and {ittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship:- I/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: – Works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards.