MILIND RATHI M.E.(Struct) M.l.E..F.I.V. FORM -2A CONSULTING [See MahaRERA order no. _of 2018) STRUCTURAL ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE DESIGNER (Sitesupervisor'scertificate) & CHARTERED ENGINEER A-1711B, Sahakari Audhyogik To, Vasahat, Old M.l.D.C., Mr. SunilR.Mantri Ajanta Road, Jalgaon (M.S.) Tel.: (0) 0257-2210979 Jalgaon. Mob. : 98230 29679 E-mail: milindrathi@redilfmail.com Quality Assurance Certificate (Certificate no for the quarter ending _ Subject: Certificate for quality of materials used and quality of Constructio and workmanship for the Work of "Rudra Square" Commercial & ~ ~ Residential building of the project situated on the Got No.150, Plot No. 6, ~~, ~ Pimprala Shiwar, Tal. & Dist. Jalgaon - 425001 admeasuring 585.00 sq.mts. area being developed by Mr. SunilR.Mantri,Jalgaon. mBmm~~~ Reference: MahaRERA Registration Number-P49900020737 Sir, I Milind Rathi, have undertaken an assignment of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of ~mm~mt9 supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and workmanship as per prescribed specifications, and as per NBC end" ' 2 or other relevant ~ code of practice. . I) Material Testing:- . •..~ ''I ~.." I have applied following mandatory checks on the basic materials, used in the construction. i) Cement- "' .. , MILIND RATHI M.E.(Struct) M.I.E.,F.IV It has been tested for its fineness, soundness, setting time, CONSULTING compressive strength etc. as per IScode 3535: 1986 or as peSTRUCTURAL other relevant IS/85/NBC code, or as per industry standards DESIGNER and its results are within the permissible limits. ~HARTERED ENGINEER A-1711B, Sahakari Audhyogik '1'1) Coarse aggregate - Vasahat,OIdM.l.D.C., AjantaRoad,Jalgaon(M.S.) It has been tested, for deleterious materials, clay lumps, Tel.: (0)0257-2210979 crushing value, impact value as per IS243011986 or as per ~~~il:::~~~:~iffmau.com other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii) Bricks/ blocks- They have been tested for water absorption, crushing strength etc. as per IS5454:1978 or as per other relevant IS/85/NBC code or as per industry standards and its results are within permissible limits. iv) Concrete I Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and IS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its ~~m9~~ results are within permissible limits. ~ v) Steel for concrete- It has been tested as per IS2062:2011 or as per other relevant Is/Bs/NBC code or as per industry standards for tensile streneth, elongation and gauge length etc. and its results are within permissible limits. vi) Testing of Other materials- Other materials like sand, crushed sand, floor tiles, fixtures and {ittings, pipes and sanitary fittings etc. (Listout all itemsmm~~m, used in this project conform to relevant IS/BS/NBC code or ~m:m~mg as per standards laid down by the Industry for a porticulor ......" ....",." .... ~ material. ~ ..- 2, Workmanship:- I hereby certify that work has been carried out under our supervisior We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3, Electrical Materials and workmanship: - ' ..... MILIND RATHI M.E.(Struct) M.I.E.,F.I.v. Works of all the electrical wiringl connections I lift installati?n I other CONSULTING electrical installations have been carried out under authorized STRUCTURAL Iregistered electrical engineer and its records has been maintained.DESIGNER The materials used conform to the relevant I.SI B.SI National Buildin8~HARTERED codes or as per industry standards. ENGINEER A-17118, Sahakari Audhyogik Vasahat, Old M.l.D.C., 4. Structural engineer:- Ajanta Road, Jalgaon (M.S.) Promoters has engaged structural engineer Mr. Milind Rathi having Tel.: (0) 0257·2210979 Mob. : 98230 29679 Licenses no. M-125145-1 having office no. 0257-2210979. E·mail: milindrathi@rediflmaD.com The structural design of buildings in this project has been done unde ~ 10. . ' his supervision. He has checked the soil report before laying PCC for ~ foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per IS 10262:2009 or as per ~~mb,~w other relevant codes as applicable. Hisperiodic checks arid certificates for STABILITYand SAFETYhave been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law. 6. Please specify materials or any other work which was not conformin_mm~~~ to the standard specifications and which was not rejected. Yours Faithfully, Milind Rathi (License No - M- 125145-1) Chartered Engineer