FORM.2A I See MahaRERA order no. of 20181 ENGINEER'S CERTIFICATE FOR QUALITY ASSURANCE (site supervisor's certificate) (To be uploaded quarterly) To, Date 31103 IZOZL N&L Associates, 55, Shivram Nagar, M.J. College Road, Jalgaon-425001. Qua litv Assu rance Certificate (Certificate noP499ooo19598 for the quarter ending 3lthMarch 212:.l Subiect :Certificate for quality of materials used and quality of Construction and workmanship for the Work of One Building(s)/ Wing(s) situated on the Plot bearing C. N. No / CTS No.1697A/l9ll + 169711912, Jalgaon demarcated by its boundaries (latitude and longitude of the end points) 4.50M Road to the North, CTS No.1697N20 to the South, 10 M Wide Road to the East, Lane to the West of at Mahabal, Taluka/District Jalgaon PIN 425001 admeasuring 318.60sq.mts. Area being developed by N&L Associates Reference: MahaRERA Registration Number- P499OOO19s9B Sir, l/ WeHEMANT JAGNNATH NYATI have undertaken an assignment of supervision of this real estate project. 1. Our Responsibility: - To carry out the work in accordance with the development permission and as per the approved plan and submit certificate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. MaterialTesting :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- It has been tested for its fineness, soundness, setting time, compressive strength etc. as per lS code 3535:1986 or as per other relevant lS/85/NBC code, or as per industry standards and its results are within the permissible limits. ii. Coarse aggregate - It has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 2430LL986 or as per other relevant IS/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks - They have been tested for water absorption, crushing strength etc. as per lS 5454:l-978 or as per other relevant lS/85/NBC code or as per industry standards and its results are within permissible limits. iv. Concrete/Ready-mix Concrete- It has been tested for compressive strength for various periods as per 15 456:2000 and lS 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- lt has been tested as per lS 2062:2011 or as per other relevant IS/BS/NBC code or as per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and fittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant IS/BS/NBC code or as per standards laid down by the industry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practice. 3. Electrical Materials and workmanship: - works of all the electrical wiring/connections/lift installation/other electrical installations have been carried out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant l.S/ B.S/ National Building codes or as per industry standards. 4. Structural engineer: - Promoters has engaged structural engineer Mr.Anand Amol Mukundhaving Licenses no. Lic No. 2Lhaving cell no 9326299499 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant. The formwork and concrete mix design has been done as per ls L0262:2OO9 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY havebeen kept record. 5. Preservation of records:- Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejeded. Yours Faithfully, \^ \t42' \X Signature of Engineer (Site Name: Hemant J. Nyati License no.16 .,t l;:f:.r;,-:rc l:.e::1i Phone no.9422279876 Place: Jalgaon