FORM 1 ARCHITECT'S CERTIFICATE To be submitted at the time of Registration of Ongoing Project and for withdrawal of Money frorn Designated Account) Date: l2-10-2O2O To TheN&LASSOCIATES 56,SHIVRAM NAGARMJ COLLAGE ROAD, JALGAON Subject: Certificate of Percentage of Completion of Construction Work of " Shree Sai Sona Plaza", 01No of Building(s) 0l_Wing(s) of the _N//A_Phase of the Project ( RERA Registration Number) situated on the Plot bearing CTS No.l697Al19/1+1697N19/2 demarcated by its boundaries(latitudeandlongitudeoftheendpoints)4.50MPATIIWAYtotheNorth,l6gTN20totheSouth,l0.0MWIDEROADtotheEast,BOLE to the West of Division JALGAON village JALGAON taluka JALGAON District - JALGAON, PIN 425001, admeasuring 318.60 sq.mts. area being developed by (Promoter's Name) Sir. VWe Anand Amol Mukund have undertaken assignment as Architect/Engineer of certifing Percentage of Completion of Construction Work of " Shree Sai Sona Plazz" the Building(s/_0_!Ving(s) of the _0_Phase of the Project, situated on the plot bearing CTS No.16974./19/1+1697N19/2, of Division JALGAON village JALGAON aluka JALGAON District - JALGAON1PIN 425001, admeasuring 318 60 sq mts area being developed by N & L ASSOCIATES as per the approved plan. 1 Following technical professionals are appointed by Owner/Promoter:- (as applicable) (i) Shri Anand Amol Mukund as Architect/Engineer (ii) Shri Anand Amol Mukund as Structural Consultant (iii) N{/s./Shri/Smt as MEP Consultant (iv) Shri SAGAR SUBHASH INGALE as Site Supervisor Based on Site Inspection, with respect to each ofthe BuildingAVing ofthe aforesaid Real Estate Project, I certifr that as on the date ofthis certificate, the Percentage ofWork done for each ofthe buildingAMing ofthe Real Estate Project as registered vide number under RERA is as per table A herein below The percentage ofthe work executed with respect to each ofthe activity ofthe entire phase is detailed in Table A and B Table - A Buildine "Shree Sai Sona Plaza' Percentage of work Sr. No Tasks/Activity done 1 Excavation 00% 2 Basement(s) and Plinth 0001 J Vlezzanine Floor 0001 4 lirst Floor 0001 5 6 number of Slabs of SuDer Structure 0001 6 .nternal walls, IntemilPlaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises; r0001 7 ianitarv Fittinss within the Flat/Premises 8001 itaircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and 8 Jndersound Water Tanks 8001 lhe extemal plumbing and extemal plaster, elevation, completion ofterraces with waterproofing ofthe 9 SuildingAMing 10001 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, compliance to conditions of environment/CRZ NOC, Finishing to t0 entranca lobby/s, plinth protection, paving ofareas appurtenant to BuildingAVing, Compound Wall and all other requirements as may be required to Obtain Occupation/Completion Certificate 6001 Table - B Intemal & Extemal Development Works in Respect of the entire Registered Phase Proposed Percentage of Sr. No Common areas and Facilities Amenities (Ym/No) Remarks work done I Intemal Roads & FootDaths {o N/A 2 Water Supply fes l00o/t J Sewerage (chamber. lines. Septic Tank. STP) fes 8001 A Storm Water Drains fes I00o/r ) LandscaDing & Tree Planting fes N/A 6 Itreet Lighting les N/A lommuniW Buildings {o N/A 8 Ireafrnent and disoosal ofsewage and sullaee water /STP {o N/A 9 lolid Waste Manasement & Disoosal tTo N/A 0 ly'ater Consewation, Rain Water Harvesting , Percolatins Well/Pit Yes IOOo/o I Snergy Management tIo N/A 2 Fire Protection and Fire Safety Requirements No N/A J Electrical Meter Room, Stb-station, Receiving Station No N/A )thers (Option to Add mor No N/A Yours Faithfully, w MRANAND MUKLTND Sigrature & Name (IN BLOCK LETTERS) OF Architect/Engineer (LicenseNo2l ) RNAND A. MUKUND J.M- First Fto Rlng Roa Mob.93262-99499