FORM 1 ARCIIITECT'S CERTIFICATE To be submitted at the time of Registration of Ongoing Project aod for withdrawal of Money from Designated Account) Date: 29/0412019 To TheN&LASSOCLq.TES. 56,SHNT,AM NAGARMJ COLLAGE ROAD, JALGAON Subject: Certifrcate of Percentage of Completion of Construction Work of " Shree Sai Sona Plaza", 01No. of Building(s) 0l_Wing(s) of the _N//A_Phase of the Project (Gujarat RERA Registration Number) situated on the Plot bearing CTS No.1697A"/19/I+1697N79/2 demarcated by its bourdaries(latitudeandlongitudeoftheendpoints)4.50MPATTIWAYtotheNorth,l69TN20totheSouth,l0.0MWIDEROADtotheEast,BOLE to the West of Division JALGAON village JALGAON taluka JALGAON District - JALGAON, PIN 425001, admeasuring 318.60 sq.mts. area being developed by (Promoter's Name) Sir, l\Ve Anand Amol Mukund have undertaken assignment as Architect/Engineer of certi$ing Peroeutage of Completion of Construction Work of " Shree Sai Sona Plaza" the Building(s)/_0 Wing(s) of the _0_Phase of the Project, situated on the plot bearing CTS No.1697A,/19/l+l697Nlgl2, of Division JAIGAON village JALGAON taluka JALGAON District - JALGAON, PIN 425001, admeasuring 318.60 sq.mts. area being developed by N & L ASSOCIATES as per the approved plan. l. Following technical professionals are appointed by OwnerlPromoteri (as applicable) (i) Shri Anand Amol Mukund as Architect/Engineer (ii) Shri Anand Amol Mukund as Skuctural Consultant (iii) IWs./Shri/Smt. as MEP Consultant (iv) Shri SAGAR SUBHASH INGALE as Site Supervrsor Based on Site Inspection, with respect to each ofthe BuildingAiling ofthe aforesaid Real Estate Project, I certi$ that as on the date ofthis certificate, the Percentage of Work done for each of the buildingAVing of the Real Estate Project as registered vide number under GuiRERA is as per table A herein below. The percentage ofthe work executed with respect to each ofthe activity ofthe entire phase is detailed in Table A and B. Table - A Building "Shree Sai Sona Plaza" Percentage ofwork Sr. No Tasks/Activity done lxcavation 10001 2 Basement(s) and Plinth 7501 3 Mezzanine Floor 001 4 First Floor 001 5 6 numberofSlabs ofSuper Structure 00/, 6 Internal walls. Internal Plaster. Floorines within Flats/?remiscs. Doors and Windows to each of the Flat/Premises 00/, 1 Sanitarv Fittirrs within the Flat/Premises 001 Staircases, Lifts Wclls a:rd Lobbies at each Floor level connecting Staircases and Lifu, Ovcrhead and Underground 8 Water Tanks l00l The extemal plumbing and cxternal plaster, elevation, completion ofterraces with waterproofing ofthe 9 BuildingAiling 001 Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, compliance to conditioos of environment/CRZ NOC, Finishing to 10 cntrance lobby/s, plinth protection, paving ofareas appurtenant to Building/IVing, Compound Wall and all othcr requirements as may bc requircd to Obtain Occupation/Completion Certificate 0o/t Table - B Internal & External Development Worla in Respect ofthe entire Registered Phase Proposed Percentage of Sr. No Common areas and tr'acilities Amenities (Yes/No) Remarks work done I htemal Roads & Footoaths No \/A 2 Water Suoolv Yes 0o/t -l lewsaqe lchamhe lines Smtic Tnnk STP\ Yes 50o/t 4 Storm Water Drains Yes 0o/r 5 Landscaping & Tree Plantine Yes Oo/r 6 Street Lishthe Yes Oo/t 7 Communiw Buildines No \I/A 8 Ireatment and disoosal ofsewase and sullace water /STP No v/A 9 Solid Waste Manasernent & DisDosal No \I/A 0 Water Conservation. Rain Water llawestins . Percolatins Well/Pit Yes Oo/( I Energy Mauaaement No \I/A Fire Protection and Fire Satbtv Requirements No i/A J ElecEical Meter Roour. Sub-station. Receivine Station No \I/A 4 f,thers (Ootion to Addkrore) No {/A Yours FaithfullV, \ \.^ MR ANANI-) MTTKITNT) Signature & Name (IN BLOCK LETTERS) OF Architect/Engineer (License No.21.)