1, Annexure A FORMl lsee regulotion 3l (To be submitted ot the time of registrotion of ongoing project and for withdrowol of money from ciesignoted account) Date:18/01/2025 To, Mr. Yogesh Pramodshonkor Desai Subject: Cerlif icate of Percentage of Completion ol Construction Work Ashtovinoyok Residency hoving MohaRERA Registration Number P49700056003 being developed by Yogesh Promodshankar Desai. 5ir, TlWehave undertaken ossignment as Architect lLicensed Surveyor of certifying Percentage of Completion of Construction work of Ashtavinayok Residency hoving MohoRERA Registrotion number P4970OO560O3 Bosed on Site inspection, wifh respect to Loyout / each of the Building A, B, C.D ond E Wing of the af,oresoid reol estote Project. f certify thot as on the dote of this cerfif icate. the Percentage af Work done f or each of the building/Wing of the Reol Estote Project under MahaRERA is os per Table A herein below. The percenfoge of the work executed with respect to each of the octivity of the entire phose is detoiled in Toble B. 2 Building Number. A Toble A To be prepored separately for each Layout I Building lWing of the Project Tasks I Activity Percenlage of Acfuol Work (?) Done (cs on dqfe of cerfif icate) 1a\ tJ_, 1 Excavotion 100% 2 Basemenfs (if any) i00% 2 Podiums (if any) U 4 Plinth 100% 5 Stilt Floor LAO% 6 Slobs of Super Structure 8A% 7 Internal walls, fnternol Plaster, Floorings, 50% Doors and windows wifhin FlafslPremises I Sonitory Fittings within the Flot/Premises o7" 9 Staircases. Lifts Wells ond Lobbies ct eoch o% Floor level Overheod ond Underground Woter Tanks 10 Externol plumbing ond externol plaster, U,'O elevation, completion of terrsces with waterproof ing of the Building I wing, LI fnstollotion of Lifts. water pumps, Fire o% Fighting Fittings ond Equipmenf os per CFO hiOC. Electricol fittings, mechonicol equipment, complionce to condifions of environment/CPZ NCC. Finishing to entronce lobby/s. plinth protecf ion, poving of oreos oppurtenont to Building / Wing. Cornpound Wcll and oll other reguirements qs may be required to complefe project os per specifications in agreement of Sale, Any other activities. J Toble B common Areos (Internol ond External Development works) in respecf of the Ragistered Phose / Project Number. Cr Common Areos ond focilities Proposed Peecentage of Actuql Detqils (Yes/No) work done (5) no (2) (3) (As on dqte of (1) Certificote) 1 Internal roods and No Nil Foo Yes 0% Z Water Sewerage (Chomber lines, Yes o% 3 c Tonk S 4 Storm Water Droins No Nil 5 Londscoping &Tree No Nil Plont 6 Street Li No Nil 7 Communi Bui No Nil q Treatment ond disPosol No Nil of sewage ond sullnge woter I Solid Waste monogement No Nil &Di 10 Woter conservotion / No Nil Rain water horvesti 11 Enerqy No Nil L7 Fire protection ond fire No Nil safetY 13 Electrical meter room, Yes o% sub-station, r eceiving staf ion. 14 Others (option to qdd more 4 Buildina Number B Table 4 To be prepored seporotely for eoch Loyout / Building lWing of the Project Percentage of Acf$al Work Done (os on dofe of cerfificate) f3) 1 Excavotion 100% 2 Bosements (if ony) tao% 3 Podiums (if any) 0 4 Plinth 100% 5 Stilt Floor 100% 6 Slcbs of Super Structure 6A% 7 fnternol wolls, Internol Ploster, Floorings, 25% Doors and windows within Flats/Premises I Sonitory Fittings within the Flot/Premises 9 Stairccses. Lifts Wells qnd Lobbies at each o% Floor level Averhead and Underground Water Tanks 10 Externol plumbing and externol ploster, a% elevotion. completion of tercaces with woterproofing of the Building / wing, 11 Installation of Lifts. water pumps, Fire o% Fighting Fittings ond Eguipment as per CFO NOC, Electrical f ittings, mechonical eguiprnent, complionce to conditions of environmenrlCRZ NOC. Finishing to entrance lobbyls. plinth protection, poving of oreos appurtencnt to Building I Wing. Conrpound Woll and oll other requrrements os may be required to complete project os per specif icctions in ogreenent of Sole, Any other octivities. Toble B Common Areos {Infernal ond Externol Development Works} in respect of the Registered Pha,se / Project Number. Sr. Common Areas ond fscilities Proposed Percentage of Actuol Details no (2) {Yes/No} work done (1) (3) (As on dote of Certif iccte) 14) 1 Internal roods ond No Nil Footpoths 1_ Waler Suoolv Yes a% 5 3 Sewerage (Chamber I ines, Yes a% 5 c Tonk.5 4 Storm Water Droins No Nil 5 Londscoping &Tree No Nil Plcntin 6 Street Li t No Nil 7 Communi Buitdi No Nil I Treotment ond disPosol No Nil of sewoge and sulloge water 9 Solid Woste management No Nil &D sal 10 Wster conservotion I No Nil Rain wster horvestin 11 Energv Manogement No Nil t? Fire protection ond fire Nc Nil safe' rements 13 Electricol meter room, Yes o% sub-station, receiving station. l4 Others (option to add more) Buildina Number € Toble A To be prepored seporotely for eoch Loyouf / Building lwing of the Project.) Sr. Tosks I ?eecentage of Actual Work Done (os on dote of cerfificote) (3) 1 Excovation toa% (. Basements if no% 3 Podiums f 0 4 Plinth 100% Stilt Floor 100% 5 Slabs of Structure ?oY. 6 fnternal wolls, fnternol Ploster, Floorings, a7" 7 Doors ond windows within Flqts/Premises 8 Sani Fftri within the Flat/Prernises o% I Stoircoses. Lifts Wells ond Lobbies ct each o% Floor level Overheod ond Underground Woter Tanks 6 10 Extarnal plumbing and externol plcster, a% elevotion, completion of terraces with woterproofing of the Building I wing, 11 fnstallotion of Lifts. water pumps, Fire a% Fighting Fittings ond Eguipment as per CFO NOC, Electricol f ittings, mechonical eguipment, compliance to conditions of environmenf /CPZ NOC. Finishing to entrance lobby / s. phnfh protection, poving of oreos oppurtenont to Building / Wing. Compound Woll and oll other requirements os may be required to complete project as per specif icotions in agrezment of Sole, Any other activities. Toble B Cornmon Areas (Internal ond Extarnsl Development Works) in respect of the Registered Phqse / Project Number. Sr. Common Areos ond focilities Proposed Percentoge of Actuol Detoils no (2) (YeslNo) work done (5) {1} (3) (As on dote of Certificote) (4) L Internal roads ond No Nil Footpoths ? Woter Supply Yes o% 3 Sewerage (Chomber lines. Yes o% Septic Tank,STP) 4 Storm Woter Droins No Nil 5 Landscoping &Tree No Nil Plonf ing 6 Street Lighting No Nil 7 Community Buildinqs No Nil I Traotment ond disposal No Nil of sewage ond sulioge water 9 Solid Woste monogement No Nil & Disposal 10 Woter conservotion / No Nil Rain woter harvesting. 11 Energy Monogement No Nil L2 Fire protection qnd fire No Nil safety requirements. 7 13 Electricol meter room, Yes a% sub-stotion, receiving stotion. L4 Others (option to add more) Buildino Number D &ble A To be prepored seporotely for eoch Loyouf / Building lwing of the Project Tcsks / certif icote) (3) L Excovotion rca% ? Bosements f 100% 3 Podiums (if ony) 0 4 Plinth no% 5 Stilt Floor too% 6 Slobs of 5 r Structure o% 7 fnternol wolls, fnternol Ploster, Floorings, o% Doo rs and windows within Flats/Premises 8 Sani Fitti within the Flat/Premises a% 9 Staircases. Lifts Wells ond Lobbies at eqch o% Floor level Overhead ond Underground Woter Tanks 10 Externol plumbing and external plaster, o% elevotion, completion of terroces with waterproofing of the Building / wing, 1i Instollotion of Lifts. water pumps, Fire oy" Fighting Fittings and Eguipment as per CFO NOC, Electrical f ittings, mechonical eguipment, compliance to conditions of environment/CPZ NOC. Finishing to entrance lobby/s. plinth protection, poving of oreas oppurtenant to Building / Wing' Compound Woll ond oll other requirements os may be reguired to complete projact os per specifications in agreement of Sole, Any other activities. B Table B Conrnon Areos (Internol and Externol Development Works) in respect of fhe Registered Phose / Projecf Number. 5r- Common Areos and fscilities Proposed Percentage of Actuol no {2) Ues/No) work done (1) (3) (As on dqte of Cerfif icote) (4) 1 fnternal noads ond No Nil Footpoths ? Wqter Supply Yes o% 3 Sew er age (Chomber I i nes, Yes o% Septic Tonk, STP) 4 Storm Woter Droins No Nil 5 Londscaping &Tree No Nil Planting 6 Street Lighting No Nil 7 Community Buildings No Nil I Treatment ond disposal No Nil of sewage and sulloge woter I Solid Woste monagement No Nil & Disposal 10 Woter conservstion / No Nil Roin water harvesting. 11 Enerqy Monagemenf No Nil 12 Fire protection and fire No Nil safety raquirements. 13 Electricol meter roor'n, Yes o% sub-station, receiving stotion. 14 Others (option to add more) 9 Building Number E Table A To be prepored seporotely for each Loyout / Building lwitE of the Projzcf.) Tosks / ActivitY Percentoge of Acfuol Work (2) Done (os on dote of certif icate) (3) 1 Excovotion 0% ? Basements t a% 3 Podiums t o% 4 Plinth a% Stilt Floor o% 5 Slabs of Structure a% 6 7 fnternol wolls, fnternol Ploster, Floorings, o% Doors and windows within Flots/Premises I 5on Fiili within the Flot/Premises o% 9 Staircoses. Lifts Wells ond Lobbies at eoch o% Floor level Overhead ond Underground Water Tqnks 10 Externol plumbing and externol ploster, o% elevation, completion of terrqces with wcterproofing of the Building l wing, 11 fnstollation of Lifts. woter pumps, Fire o% Fighting Fittings and Equipment os per CFO NOC, Electricsl f ittings, mechanicol eguipment, complionce to conditions of environmenf /CPZ NOC. Finishing to entrance lobby/s. plinth protection, poving of oreos oppurtenont to Building / Wing. Compound Woll ond oll other requirements as may be required to complete project os per specificcf ions in agreement of Sole, Any other activities. 1n Table B Common Areos (Internol and Externol beveloprnent Works) in raspect of the Registered Phose I ProJect Number. Common Arccs ond facilities Percentag* of Actusl Defails {t}, ' ' ,. urork done (As on dat* of Certificote) (4) 1 Internol roods ond No Nil Footpoths 2 Water Supply Yes a% 3 Seweroge lines, Yes A"/" Saptic Tonk, STP) 4 Storm VUoter Droins No Nil 5 Londscoping & Tree No NiI Plonting 6 Street Lighting No Nil 7 Communify Buildinqs No NiI I Treotment and disposcl No Nil af sewage and sulloge water I Solid Waste monagement No Nil & Disposal 1CI \,Voter conservotion,/ No Nil Roin woter horvesting. 11 Energy /trlanogement No Nil L2 Fire protection and fire No Nil sofety reguiremenll_. 15 Electrical meter room, Yes a% sub-station, receiving stqtion. 14 Others {cption to add more) $igru?ul"cwrd t*rsn€ sf LSI AR- retr?r,ar{A '' :hitffil ;ffi Agreed ond Accepted by: '+^P'z \ YOCESH }ESAI PROi'IOTER A$HTAVI NAYAK R ESIDENCY Address: Viral Vihsr, Khodoi lyloto Rood. Nondurbar Signoture of Promoter Aadhar No.: 6657 17CI?5817 Nsme: Yogesh Promodshankcr besai Pon no: CHMPP7540K Dafe; l$/91/2025