13S{}, firrst ltrl*;:r, F***r trxrr;:t t{*sp:it*l wx $wmrm wwrxw&rw*m&$wwx L-a** FJ* 5, tlt"tiit S -,+?4 t}01 (fv{.$.} il*rtsultrrtg ilnginl**r r -t{xl i*?{S;}} *. 2;l*fi?7 Flr*g:r. Hr $-*+rnarit !**i Date.15105l?023 FORM.2A I See MahaRERA order no. of 20{81 ENGINHER'S CERTIFICATE FOR QUALITY ATSURANCE (site supervisorns certificate) To, The M/s. Vimal Developers, Prop. Rajendra Vasantrao Khankari 47 87 I 1 5 Bhide Baug, Deopur, Dhu \e,424AA2, Quality Assurance Ceftifi cate (Certificate no. 03 for the quarter ending 21-22) Subject " Certificate for quality of materials used and quality of Construction and workmanship for the Work of " Vasudha Vihar " No. of Building(s)^01 the project situated on the plot bearing C.T.S. No.157/ $urvey Na.574l2Plot no.28 demarcated by its boundaries (latitude and longitude of the end points) 9 Mtr Road to the North,Colony Road to the $outh,Plot no 27 to the East,Plot no 29 to the West of Division.Nasik village Dhule (CT) taluka Dhule District Dhule P1N.424001 admeasurin9.473.9 sq.mtrs. area being Plot Owner.Dr Hemantrao Bhaskarrao Deshmukh Project developed by Mr Rajendra Vas ntrao Khanka ri Prop.Vi mal Developers Reference: MahaRERA Registration Number- P49800013520 $ir, l/ We Er Hemant B lsai have undertaken an assignment of supervision of this realestate project. - 1" Our Responsibility: To carry out the work in accordance with the development permission and as per the approved plan and submit ceftficate of supervision of work and to carry out material testing in-situ or in the authorized laboratory and to ensure quality of work and 1. Material resting :- l/we, have applied following mandatory checks on the basic materials, used in the construction. i. Cement- lt has been tested for its fineness, soundness, setting time, compressivestrength etc. as per l$ code 3535:1986 or as per other relevant lSl85/NBC code, or as per industry standards and its results are within the permissible limits. ii" Coarse aggregate - lt has been tested, for deleterious materials, clay lumps, crushing value, impact value as per lS 243011986 or as per other relevant I$/BS/NBC code or as per industry standards and its results are within the permissible limits. iii. Bricks/ blocks * They have been tested for water absorption, crushing strength etc. as per l$ 5454:1978 or as per other relevant I$/8S/NBC code or as per industry standards and its results are within permissible limits. iv. ConereteiReady-mix Concrete- lt has been tested for compressive strength for various periods as per 15456:2000 and l$ 1199 or as per other relevant IS/BS/NBC codes, as per industry standards and its results are within permissible limits. v. Steel for concrete- lt has been tested as per lS 2062:2011 or as per other relevant IS/BSINBC code or a$ per industry standards for tensile strength, elongation and gauge length etc. and its results are within permissible limits. vi. Testing of Other materials Other materials like sand, crushed sand, floor tiles, fixtures and {ittings, pipes and sanitary fittings etc. (List out all items) used in this project conform to relevant l$lBS/NBC code or as per standards laid down by the lndustry for a particular material. 2. Workmanship:- l/ we hereby certify that work has been carried out under our supervision. We further certify that workmanship and quality is satisfactory and up to the mark and the work has been acceptable within the permissible limits of deviations as per relevant code of practiee. 3. Electrical Materials and workmanship: works of all the electrical wiringiconnectionsilift installationlother electrical installations have been canied out under authorized/registered electrical engineer and its records has been maintained. The materials used conform to the relevant LS1 B.S/ National Building codes or as per industry standards" - 4, $tructural engineer: Promoters has engaged structural engineer Mr.Abhay V Bhadalikar having office cell no 9422752529 The structural design of buildings in this project has been done under his supervision. He has checked the soil report before laying PCC for foundation in consultation with soil consultant, The formwork and concrete mix design has been done as per ls 10262:2009 or as per other relevant codes as applicable. His periodic checks and certificates for STABILITY and SAFETY have been kept on record. 5. Preservation of records: - Record of all test results of this project have been properly kept in the prescribed formats and will be preserved at least up to the defect liability period or for the period as required by any other provision of law 6. Please specify materials or any other item of work which were not conforming to the standard specifications and which were not rejeded. Yours Faithfully, Signature of Engineer HEMANT B.ISAI Consulting Engineer 1380,1stFloor, Near Panat Hosfiital,Dhule License No.'00219